[SENSe:]TXPower

Last Updated: June 19, 2009

These commands provide test set specific settings for the Transmit Power (TXP) measurement.

[SENSe:]TXPower:AVERage[:STATe][?]

Sets/queries whether or not averaging is performed on the Tx Power measurement.

The number of averages is set using [SENSe:]TXPower:AVERage:COUNt[?].

Setting Range: 0 | OFF | 1 | ON

Query Range: 0 | 1

*RST Setting: 0 | OFF

Test Set Requirements: N8300A Wireless Networking Test Set Version A.02 and above

Example:

TXPower:AVERage ON

Turns averaging on for the Tx Power measurement.

[SENSe:]TXPower:AVERage:COUNt[?]

Sets/queries the number of averages to be made for the Tx Power measurement.

Averaging can be switched on or off using [SENSe:]TXPower:AVERage[:STATe][?].

Setting Range: 1 to 10,000

Query Range: 1 to 10,000

Resolution: 1

*RST Setting: 10

Test Set Requirements: N8300A Wireless Networking Test Set Version A.02 and above

Example:

TXPower:AVERage:COUNt 20

Sets the average count to 20 for the Tx Power measurement.

[SENSe:]TXPower:TRIGger:SOURce[?]

Sets/queries the type of trigger source for the Tx Power measurement.  

Refer to TRIGger for more information on configuring the trigger.

Setting Range: EXTernal | IMMediate | RFBurst

Query Range: EXT | IMM | RFB

*RST Setting: IMMediate

Test Set Requirements: N8300A Wireless Networking Test Set Version A.02 and above

Example:

TXPower:TRIGger:SOURce RFBurst

Sets the RFBurst triggering source for the Tx Power measurement.