Forward Traffic Rate in IS-856 Test Operating Mode

Forward Traffic Rate in IS-856 Test Operating Mode

Last updated: November 10, 2006

The Forward Traffic Rate determines the rate (and number of slots) at which the forward traffic packets are transmitted by the test set in IS-856 Test Operating Mode .

You must select a Forward Traffic Rate as listed in the table below to match your AT's configuration because there's no signaling exchanged between the AT and the test set when in IS-856 test mode. What you set (including forward data rate, number of slots per physical packet, as well as the corresponding modulation type) is then displayed on the Call Setup screen in the Configuration Information window.

Forward Traffic Data Rates in IS-856 Test Mode
Forward Traffic Data Rate (kbps) Slots per Physical Packet Modulation Type
38.4 16 QPSK
76.8 8 QPSK
153.6 4 QPSK
307.2 2 QPSK
307.2 4 QPSK
614.4 1 QPSK
614.4 2 QPSK
921.6 2 8-PSK
1228.8 1 QPSK
1228.8 2 16-QAM
1843.2 1 8-PSK
2457.6 1 16-QAM

Related Topics


GPIB command: CALL:TEST856:TRAFfic[:FORWard]:DRATe

Manual Operation: How Do I Change Parameters in IS-856 Test Operating Mode?

IS-856 Test Operating Mode

To set the forward traffic data rate in the Active Cell operating mode, see FTAP Rate .