FETCh:DOWQuality

FETCh:DOWQuality

Last updated: July 23, 2008

GPIB Command Conventions

FETCh:DOWQuality[:ALL]?

FETCh:DOWQuality(:INTegrity|:RHO|:FERRor|:TERRor|:FEEDthrough|:PERRor|:MERRor|:EVM)?

Function

Queries the waveform quality measurement results. [:ALL] returns measurement results in the following order: integrity, rho, frequency error, time error (in seconds), carrier feedthrough, phase error (in degrees), magnitude error, and EVM. For details, see Waveform Quality Measurement Results .

If the multi-measurement state is on, each result represents the average of a number of waveform quality measurements. Multi-measurement state, by default, is off. To set up multi-measurements, see SETup:DOWQuality:COUNt[:SNUMber] .

Instead of returning [:ALL] results, you may query the result for any particular measurement individually using the associated keyword, such as :RHO. If multi-measurement state is on, you may query the average, maximum, minimum or standard deviation for any particular measurement result individually by adding the :MAXimum, :MINimum or :SDEViation keyword.

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above

Query

Integrity

  • Range: 0 to 23
  • Resolution: 1

Rho

  • Range: 0.0000 to 1.0000, 9.91 E+37
  • Resolution: 0.0001

Frequency Error (in Hz)

  • Range: -9999.0 to 9999.0 Hz, 9.91 E+37
  • Resolution: 0.1 Hz

Time Error (in s)

  • Range: -99.99 E-6 to 99.99 E-6 s, 9.91 E+37
  • Resolution: 0.01 E-6 s

Carrier Feedthrough

  • Range: -100.00 to 0.00 dBc, 9.91 E+37
  • Resolution: 0.01 dB

Phase Error

  • Range: 0.00 to 359.99 degrees, 9.91 E+37
  • Resolution: 0.01 degrees

Magnitude Error

  • Range: 0.00 to 100.00%, 9.91 E+37
  • Resolution: 0.01%

Error Vector Magnitude (EVM)

  • Range: 0.00 to 100.00%, 9.91 E+37
  • Resolution: 0.01%

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality?" 
! Returns integrity, rho, frequency error, time error, carrier feedthrough, phase error, 
! magnitude error, EVM (or average for each if multi-meas is on).
 
OUTPUT 714;"FETCh:DOWQuality:RHO?"
! Returns the rho result
! (or average rho result if multi-measurement state is on).
 
OUTPUT 714;"FETCh:DOWQuality:TERRor:MAXimum?"
! Returns the maximum time error measurement result
! (useful only if multi-measurement state is on).

FETCh:DOWQuality:PAYLoad?

Function

Queries the actual R-Data payload size (in bits) that the test set detects from the R-RRI channel (R-RRI channel carries the payload size and sub-packet identifier information) when measuring subtype 2 waveform quality. The R-Data payload size determines the modulation and walsh codes used on the R-Data channel. For details, see Waveform Quality Measurement Results .

If multi-measurement state is on, you may query the average, maximum, minimum or standard deviation for the payload size result by adding the :MAXimum, :MINimum or :SDEViation keyword. Multi-measurement state is off by default. To set up multi-measurements, see SETup:DOWQuality:COUNt[:SNUMber] .

Unlike most of other waveform quality measurement results (such as rho, frequency error, etc.), the payload size result can not be queried with FETCh:DOWQuality[:ALL]? command.

Requirements

Test Application Revision: A.06 and above, with the required feature license
Lab Application Revision: A.03 and above

Query

Payload Size (bits)

  • Range: 128, 256, 512, 768, 1024, 1536, 2048, 3072, 4096, 6144, 8192, 12288, 9.91 E+37 (NAN)
  • Resolution: 1.0

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:PAYLoad?"
! Returns R-Data payload size result
! (or average payload size result if multi-measurement state is on).
 
OUTPUT 714;"FETCh:DOWQuality:PAYLoad:MAXimum?"
! Returns the maximum payload size measurement result
! (useful only if multi-measurement state is on).

FETCh:DOWQuality:ICOunt?

Function

Queries the intermediate count of measurements completed in a multi-measurement. See Measurement Progress Report .

Requirements

Test Application Revision: A.01.20 and above

Query

Range: 0 to 999

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:ICOUNt?" 

FETCh:DOWQuality:EVM:TRACe?

Function

Queries the EVM of 2048 chips during the measurement slot of the waveform quality measurement. See Measurement Progress Report .

Requirements

Test Application Revision: A.09. and above

Query

Range: 0 to 100 for each EVM of the 2048 chips

Programming Example

 
 
OUTPUT 714;"FETCh:DOWQuality:EVM:TRACe?" 

FETCh:DOWQuality:CDPower:ACKChannel[:REVerse]?

FETCh:DOWQuality:CDPower:DATA[:REVerse]?

FETCh:DOWQuality:CDPower:DRCChannel[:REVerse]?

FETCh:DOWQuality:CDPower:DSCChannel[:REVerse]?

FETCh:DOWQuality:CDPower:PILot[:REVerse]?

FETCh:DOWQuality:CDPower:PILot:AUXiliary[:REVerse]?

FETCh:DOWQuality:CDPower:RRIChannel[:REVerse]?

Function

These commands return code domain power measurement results for each of the reverse channels. The Subtype 0 reverse channels consist of the R-Pilot, R-RRI, R-DRC, R-ACK and R-Data and subtype 2 reverse channels consist of the R-Pilot, R-RRI, R-DRC, R-ACK, R-DSC, R-Aux Pilot and R-Data. So when measuring subtype 0 physical layer, querying R-Aux Pilot and R-DSC channels always returns 9.91E+37 (indicating not available).

The command for each channel returns 7 comma separated values, in the following order: modulation channel, Walsh code, spread factor, code domain power (dB), total code domain power (dB), normalized total code domain power (dB), and normalized total code domain power relative to R-Pilot (dB). See Code Domain Power Tabular Data for more information about these measurement results.

Note that when measuring subtype 2 R-Data channel with modulation type other than B4, the FETCh:DOWQuality:CDPower:DATA? command returns 7 comma separated values in the following order: modulation type, walsh code (9.91E+37), spread factor (9.91E+37), code domain power (9.91E+37), total code domain power (dB) of all walsh codes, normalized total code domain power (dB), and normalized total code domain power relative to R-Pilot (dB). The walsh code, spread factor and code domain power are always returned as 9.91E+37 (indicating not available) because the R-Data channel with modulation type other than B4 use more than one walsh channels (see Subtype 2 R-Data Packet Size, Modulation Type and Walsh Codes ). To determine the normalized total code domain power relative to R-Pilot for individual walsh channels that constitute R-Data channel, use FETCh:DOWQuality:CDPower:DATA[:REVerse]:RTPilot? .

If the multi-measurement state is on, the results are the average of a number of code domain power measurements. Multi-measurement state is off by default. To set up multi-measurements, see SETup:DOWQuality:COUNt[:SNUMber] .

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above
Test Application Revision: A.06 and above, with the required feature license: Support for new subtype 2 reverse channels: R-DSC and R-Aux Pilot channels
Lab Application Revision: A.03 and above: Support for subtype 2 reverse channels: R-DSC and R-Aux Pilot channels

Query

Range:

For all of the Subtype 0 Reverse Channels:

  • Modulation Channel: 0=I, 1=Q; 9.91 E+37 (not available)
  • Walsh code: 0 to 15; 9.91 E+37 (not available)
  • Spread Factor: 4, 8, 16; 9.91 E+37 (not available)
  • Code Domain Power: -100.0 to 0.0 dB; 9.91 E+37 (not available)
  • Total Code Domain Power: -100.0 to 0.0 dB; 9.91 E+37 (not available)
  • Normalized Total Code Domain Power: -100.0 to 0.0 dB; 9.91 E+37 (not available)
  • Normalized Total Code Domain Power Relative to R-Pilot: -100.0 to +100.0 dB; 9.91 E+37 (not available)

For Subtype 2 R-Data Channel with modulation type B4 and all other Subtype 2 Reverse Channels:

  • Modulation Channel: 0=I, 1=Q; 9.91 E+37 (not available)
  • Walsh code: 0 to 31; 9.91 E+37 (not available)
  • Spread Factor: 2, 4, 8, 16, 32; 9.91 E+37 (not available)
  • Code Domain Power: -100.0 to 0.0 dB; 9.91 E+37 (not available)
  • Total Code Domain Power: -100.0 to 0.0 dB; 9.91 E+37 (not available)
  • Normalized Total Code Domain Power: -100.0 to 0.0 dB; 9.91 E+37 (not available)
  • Normalized Total Code Domain Power Relative to R-Pilot: -100.0 to +100.0 dB; 9.91 E+37 (not available)

For Subtype 2 R-Data Channel with modulation type other than B4:

  • Modulation Type: 0=I, 1=Q, 2=Q4, 3=Q2, 4=Q4Q2, 5=E4E2; 9.91 E+37 (not available)
  • Walsh code: 9.91 E+37 (not available)
  • Spread Factor: 9.91 E+37 (not available)
  • Code Domain Power: 9.91 E+37 (not available)
  • Total Code Domain Power: -100.0 to 0.0 dB; 9.91 E+37 (not available)
  • Normalized Total Code Domain Power: -100.0 to 0.0 dB; 9.91 E+37 (not available)
  • Normalized Total Code Domain Power Relative to R-Pilot: -100.0 to +100.0 dB; 9.91 E+37 (not available)

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPower:PILot?"
! Queries the R-Pilot code domain power measurement results.
 
OUTPUT 714;"FETCh:DOWQuality:CDPower:ACKChannel?"
! Queries the R-ACK code domain power measurement results.

FETCh:DOWQuality:CDPower:DATA[:REVerse]:RTPilot?

Function

Queries the normalized total code domain power relative to R-Pilot for individual walsh channels that constitute R-Data channel. The R-Data channel can occupy up to 4 walsh channels (that is, 4 bins) depending upon the R-Data modulation type (see Subtype 2 R-Data Packet Size, Modulation Type and Walsh Codes ).

This query returns 5 comma separated values which are R-Data modulation channel/type followed by up to 4 power values (the normalized total code domain power relative to R-Pilot for individual walsh channels of R-Data, see Bin Delta Pilot (only available for subtype 2 physical layer R-Data channel) ). If R-Data consists of less than 4 walsh channels, 9.91 E+37 (NAN) results are returned for the remaining values.

  • Modulation Channel or Type:
    • 0=I channel (indirectly indicating B4 modulation. This value is never returned because R-Data is allocated to Q channel for subtype 0 physical layer and for subtype 2 physical layer using B4 modulation)
    • 1=Q channel (indirectly indicating B4 modulation. This value is returned for R-Data channel for subtype 0 physical layer and for subtype 2 physical layer using B4 modulation)
    • 2 = Q4 modulation (only available for subtype 2 physical layer)
    • 3 = Q2 modulation (only available for subtype 2 physical layer)
    • 4 = Q4Q2 modulation (only available for subtype 2 physical layer)
    • 5 = E4E2 modulation (only available for subtype 2 physical layer)
  • 4 power values represent the following walsh channels based on the modulation type:
    • B4: power values returned for <Q:2 SF=4 >, <NAN>, <NAN>, <NAN>
    • Q4: power values returned for <I:2 SF=4 >, <Q:2 SF=4 >, <NAN>, <NAN>
    • Q2: power values returned for <I:1 SF=2 >, <Q:1 SF=2 > , <NAN>, <NAN>
    • Q4Q2: power values returned for <I:2 SF=4 >, <I:1 SF=2 >, <Q:2 SF=4 >, <Q:1 SF=2 >
    • E4E2: power values returned for <I:2 SF=4 >, <I:1 SF=2 >, <Q:2 SF=4 >, <Q:1 SF=2

To determine normalized total R-Data code domain power relative to R-Pilot (dB), use FETCh:DOWQuality:CDPower:DATA[:REVerse]? command.

If the multi-measurement state is on, the results are the average of a number of code domain power measurements. Multi-measurement state is off by default. To set up multi-measurements, see SETup:DOWQuality:COUNt[:SNUMber] .

Requirements

Test Application Revision: A.06 and above, with the required feature license
Lab Application Revision: A.03 and above

Query

Range:

  • Modulation Channel or Type (for details, see the description above)
    0 = I, 1=Q, 2=Q4, 3=Q2, 4=Q4Q2, 5=E4E2, 9.91E+37 (not available)
  • Power: -100.0 to 100.0 dB; 9.91 E+37
    Resolution: 0.01 dB

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPower:DATA:RTPilot?"
! Returns 5 comma separated values, representing
! R-Data modulation type, the normalized total code domain power
! relative to R-Pilot for individual bins that make up R-Data channel.

FETCh:DOWQuality:CDPower:ICHannel:BIN? <bin num>

Function

Queries the I channel code domain power results for a specific bin. The results returned in the order of active/inactive, Walsh code, spread factor and power (dB), are the same as those returned for every bin using the FETCh:DOWQuality:CDPower[16]:ICHannel[:ALL]? or FETCh:DOWQuality:CDPower32:ICHannel[:ALL]? query.

The range of <bin num> is 0 to 15 (for subtype 0 physical layer) and 0 to 31 (for subtype 2 physical layer).

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above
Test Application Revision: A.06 and above, with the required feature license: Support for subtype 2 physical layer
Lab Application Revision: A.03 and above: Support for subtype 2 physical layer

Query

Range:
Subtype 0 Physical Layer: see FETCh:DOWQuality:CDPower[16]:ICHannel[:ALL]?
Subtype 2 Physical Layer: see FETCh:DOWQuality:CDPower32:ICHannel[:ALL]?

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPower:ICHannel:BIN? 2"
! Queries the I channel code domain power results for bin 2.

FETCh:DOWQuality:CDPower:ICHannel:COUNt[:BIN]?

Function

This query indicates how many I channel bins contain measurement data. For example, if 13 is returned, I channel bins 0 through 12 contain measurement data and bins 13 through 15 (if for subtype 0 measurement) or bins 13 through 31 (if for subtype 2 measurement) contain 9.91 E+37 results.

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above
Test Application Revision: A.06 and above, with the required feature license: Support for subtype 2 physical layer
Lab Application Revision: A.03 and above: Support for subtype 2 physical layer

Query

Range: 0 to 16 (for subtype 0 physical layer); 0 to 32 (for subtype 2 physical layer)

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPower:ICHannel:COUNt?"
! Returns the number of assigned bins (containing measurement results)

FETCh:DOWQuality:CDPower:QCHannel:BIN? <bin num>

Function

Queries the Q channel code domain power results for a specific bin. The results returned in the order of: active/inactive, Walsh code, spread factor and power (dB), are the same as those returned for every bin using the FETCh:DOWQuality:CDPower[16]:QCHannel[:ALL]? or FETCh:DOWQuality:CDPower32:QCHannel[:ALL]? query.

The range of <bin num> is 0 to 15 (for subtype 0 physical layer) and 0 to 31 (for subtype 2 physical layer).

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above
Test Application Revision: A.06 and above, with the required feature license: Support for subtype 2 physical layer
Lab Application Revision: A.03 and above: Support for subtype 2 physical layer

Query

Range:
Subtype 0 Physical Layer: see FETCh:DOWQuality:CDPower[16]:QCHannel[:ALL]?
Subtype 2 Physical Layer: see FETCh:DOWQuality:CDPower32:QCHannel[:ALL]?

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPower:QCHannel:BIN? 13"
!Queries the Q channel code domain power results for bin 13.

FETCh:DOWQuality:CDPower:QCHannel:COUNt[:BIN]?

Function

This query indicates how many Q channel bins contain measurement data. For example, if 13 is returned, Q channel bins 0 through 12 contain measurement data and bins 13 through 15 (if for subtype 0 measurement) or bins 13 through 31 (if for subtype 2 measurement) contain 9.91 E+37 results.

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above
Test Application Revision: A.06 and above, with the required feature license: Support for subtype 2 physical layer
Lab Application Revision: A.03 and above: Support for subtype 2 physical layer

Query

Range: 0 to 16 (for subtype 0 physical layer); 0 to 32 (for subtype 2 physical layer)

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPower:QCHannel:COUNt?"
! Returns the number of assigned bins (containing measurement results)

FETCh:DOWQuality:CDPower[16]:ICHannel[:ALL]?

Function

Queries the subtype 0 physical layer code domain power measurement results for all 16 bins on I channel.

This query returns 64 comma separated values. These represent 4 values for each of 16 bins. The 4 values returned for each bin are: active/inactive, Walsh code, spread factor, and power (dB). See Code Domain Power Measurement Results Available by Numbered Bins for more information about these measurement results.

There are frequently fewer than 16 bins with measurement data. For any unassigned bins (bins that don't contain measurement results), four 9.91 E+37 results are returned instead of data. This allows the query to always return 64 results regardless of how many bins contain measurement data. The FETCh:DOWQuality:CDPower:ICHannel:COUNt[:BIN]? command allows you to determine the total number of assigned bins (bins containing measurement results).

If the multi-measurement state is on, the results are the average of a number of code domain power measurements. Multi-measurement state is off by default. To set up multi-measurements, see SETup:DOWQuality:COUNt[:SNUMber] .

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above

Query

Range:

  • Active/Inactive: 0 = inactive, 1 = active; 9.91 E+37 (not available)
  • Walsh code: 0 to 15; 9.91 E+37
  • Spread Factor: 4, 8, 16; 9.91 E+37
  • Power: -100.0 to 0.0 dB; 9.91 E+37

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPower:ICHannel?"
! Returns 1 or 0, Walsh code, spread factor, and power for bin 0.
! Then returns the same for bin 1, and repeats until the values for the last bin
! (bin 15) have been returned
! for a total of 64 comma separated values)

FETCh:DOWQuality:CDPower[16]:QCHannel[:ALL]?

Function

Queries the subtype 0 physical layer code domain power measurement results for all 16 bins on Q channel.

This query returns 64 comma separated values. These represent 4 values for each of 16 bins. The 4 values returned for each bin are: active/inactive, Walsh code, spread factor, and power (dB). See Code Domain Power Measurement Results Available by Numbered Bins for more information about these measurement results.

There are frequently fewer than 16 bins with measurement data. For any unassigned bins (bins that don't contain measurement results), four 9.91 E+37 results are returned instead of data. This allows the query to always return 64 results regardless of how many bins contain measurement data. The FETCh:DOWQuality:CDPower:QCHannel:COUNt[:BIN]? command allows you to determine the total number of assigned bins (bins containing measurement results).

If the multi-measurement state is on, the results are the average of a number of code domain power measurements. Multi-measurement state is off by default. To set up multi-measurements, see SETup:DOWQuality:COUNt[:SNUMber] .

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above

Query

Range:

  • Active/Inactive: 0 = inactive, 1 = active; 9.91 E+37 (not available)
  • Walsh code: 0 to 15; 9.91 E+37
  • Spread Factor: 4, 8, 16; 9.91 E+37
  • Power: -100.0 to 0.0 dB; 9.91 E+37

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPower:QCHannel?"
! Returns 1 or 0, Walsh code, spread factor, and power for bin 0.
! Then returns the same for bin 1, and repeats until the values for the last bin
! (bin 15) have been returned
! (for a total of 64 comma separated values)

FETCh:DOWQuality:CDPower32:ICHannel[:ALL]?

Function

Queries the subtype 2 physical layer code domain power measurement results for all 32 bins on I channel.

This query returns 128 comma separated values. These represent 4 values for each of 32 bins. The 4 values returned for each bin are: active/inactive, Walsh code, spread factor, and power (dB). See Code Domain Power Measurement Results Available by Numbered Bins for more information about these measurement results.

There are frequently fewer than 32 bins with measurement data. For any unassigned bins (bins that don't contain measurement results), four 9.91 E+37 results are returned instead of data. This allows the query to always return 128 results regardless of how many bins contain measurement data. The FETCh:DOWQuality:CDPower:ICHannel:COUNt[:BIN]? command allows you to determine the total number of assigned bins (bins containing measurement results).

If the multi-measurement state is on, the results are the average of a number of code domain power measurements. Multi-measurement state is off by default. To set up multi-measurements, see SETup:DOWQuality:COUNt[:SNUMber] .

Requirements

Test Application Revision: A.06 and above, with the required feature license
Lab Application Revision: A.03 and above

Query

Range:

  • Active/Inactive: 0 = inactive, 1 = active; 9.91 E+37 (not available)
  • Walsh code: 0 to 31; 9.91 E+37
  • Spread Factor: 2, 4, 8, 16, 32; 9.91 E+37
  • Power: -100.0 to 0.0 dB; 9.91 E+37

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPower32:ICHannel?"
! Returns 128 comma separated values, each four values represent
! 1 or 0, Walsh code, spread factor, and power for each of 32 bins.

FETCh:DOWQuality:CDPower32:QCHannel[:ALL]?

Function

Queries the subtype 2 physical layer code domain power measurement results for all 32 bins on Q channel.

This query returns 128 comma separated values. These represent 4 values for each of 32 bins. The 4 values returned for each bin are: active/inactive, Walsh code, spread factor, and power (dB). See Code Domain Power Measurement Results Available by Numbered Bins for more information about these measurement results.

There are frequently fewer than 16 bins with measurement data. For any unassigned bins (bins that don't contain measurement results), four 9.91 E+37 results are returned instead of data. This allows the query to always return 128 results regardless of how many bins contain measurement data. The FETCh:DOWQuality:CDPower:QCHannel:COUNt[:BIN]? command allows you to determine the total number of assigned bins (bins containing measurement results).

If the multi-measurement state is on, the results are the average of a number of code domain power measurements. Multi-measurement state is off by default. To set up multi-measurements, see SETup:DOWQuality:COUNt[:SNUMber] .

Requirements

Test Application Revision: A.06 and above, with the required feature license
Lab Application Revision: A.03 and above

Query

Range:

  • Active/Inactive: 0 = inactive, 1 = active; 9.91 E+37 (not available)
  • Walsh code: 0 to 31; 9.91 E+37
  • Spread Factor: 2, 4, 8, 16, 32; 9.91 E+37
  • Power: -100.0 to 0.0 dB; 9.91 E+37

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPower32:QCHannel?"
! Returns 128 comma separated values, each four values represent
! 1 or 0, Walsh code, spread factor, and power for each of 32 bins

FETCh:DOWQuality:CDPNoise:ICHannel:BIN? <bin num>

Function

Queries the I channel code domain power + noise measurement results for a specific bin. The results returned in the order of Walsh code, spread factor, noise power (dB) and power (dB), are the same as those returned for every bin using the FETCh:DOWQuality:CDPNoise[16]:ICHannel[:ALL]? or FETCh:DOWQuality:CDPNoise32:ICHannel[:ALL]? query.

The range of <bin num> is 0 to 15 (for subtype 0 physical layer) and 0 to 31 (for subtype 2 physical layer).

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above
Test Application Revision: A.06 and above, with the required feature license: Support for subtype 2 physical layer
Lab Application Revision: A.03 and above: Support for subtype 2 physical layer

Query

Range:
Subtype 0 Physical Layer: see FETCh:DOWQuality:CDPNoise[16]:ICHannel[:ALL]?
Subtype 2 Physical Layer: see FETCh:DOWQuality:CDPNoise32:ICHannel[:ALL]?

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPNoise:ICHannel:BIN? 13"
! Queries the I channel code domain power + noise results for bin 13.

FETCh:DOWQuality:CDPNoise:ICHannel:COUNt[:BIN]?

Function

This query indicates how many I channel bins contain measurement data. For example, if 13 is returned, Q channel bins 0 through 12 contain measurement data and bins 13 through 15 (if for subtype 0 measurement) or bins 13 through 31 (if for subtype 2 measurement) contain 9.91 E+37 results.

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above
Test Application Revision: A.06 and above, with the required feature license: Support for subtype 2 physical layer
Lab Application Revision: A.03 and above: Support for subtype 2 physical layer

Query

Range: 0 to 16 (for subtype 0 physical layer); 0 to 32 (for subtype 2 physical layer)

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPNoise:ICHannel:COUNt?"
! Returns the number of assigned bins (containing measurement results)

FETCh:DOWQuality:CDPNoise:QCHannel:BIN? <bin num>

Function

Queries the Q channel code domain power + noise results for a specific bin. The results returned in the order of Walsh code, spread factor, noise power (dB) and power (dB), are the same as those returned for every bin using the FETCh:DOWQuality:CDPNoise[16]:QCHannel[:ALL]? or FETCh:DOWQuality:CDPNoise32:QCHannel[:ALL]? query.

The range of <bin num> is 0 to 15 (for subtype 0 physical layer) and 0 to 31 (for subtype 2 physical layer).

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above
Test Application Revision: A.06 and above, with the required feature license: Support for subtype 2 physical layer
Lab Application Revision: A.03 and above: Support for subtype 2 physical layer

Query

Range:
Subtype 0 Physical Layer: see FETCh:DOWQuality:CDPNoise[16]:QCHannel[:ALL]?
Subtype 2 Physical Layer: see FETCh:DOWQuality:CDPNoise32:QCHannel[:ALL]?

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPNoise:QCHannel:BIN? 13"
! Queries the Q channel code domain power + noise results for bin 13.

FETCh:DOWQuality:CDPNoise:QCHannel:COUNt[:BIN]?

Function

This query indicates how many Q channel bins contain measurement data. For example, if 13 is returned, Q channel bins 0 through 12 contain measurement data and bins 13 through 15 (if for subtype 0 measurement) or bins 13 through 31 (if for subtype 2 measurement) contain 9.91 E+37 results.

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above
Test Application Revision: A.06 and above, with the required feature license: Support for subtype 2 physical layer
Lab Application Revision: A.03 and above: Support for subtype 2 physical layer

Query

Range: 0 to 16 (for subtype 0 physical layer); 0 to 32 (for subtype 2 physical layer)

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPNoise:QCHannel:COUNt?"
! Returns the number of assigned bins (containing measurement results)

FETCh:DOWQuality:CDPNoise[16]:ICHannel[:ALL]?

Function

Queries the subtype 0 physical layer code domain power + noise measurement results for all 16 bins on I channel.

This query returns 64 comma separated values. These represent 4 values for each of 16 bins. The 4 values returned for each bin are: Walsh code, spread factor, noise power (dB) and power (dB). See Code Domain Power + Noise Measurement Results Available Programmatically for more information about these measurement results.

There are frequently fewer than 16 bins with measurement data. For any unassigned bins (bins that don't contain measurement results), four 9.91 E+37 results are returned instead of data. This allows the query to always return 64 results regardless of how many bins contain measurement data. The FETCh:DOWQuality:CDPNoise:ICHannel:COUNt[:BIN]? command allows you to determine the total number of assigned bins (bins containing measurement results).

If the multi-measurement state is on, the results are the average of a number of code domain power measurements. Multi-measurement state is off by default. To set up multi-measurements, see SETup:DOWQuality:COUNt[:SNUMber] .

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above

Query

Range:

  • Walsh code: 0 to 15; 9.91 E+37
  • Spread Factor: 4, 8, 16; 9.91 E+37
  • Noise Power: -100.0 to 0.0 dB; 9.91 E+37
  • Power: -100.0 to 0.0 dB; 9.91 E+37

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPNoise:ICHannel?"
! Returns Walsh code, spread factor, noise power and power for bin 0.
! Then returns the same for bin 1, and repeats until the values for the last bin
! (bin 15) have been returned
! (for a total of 64 comma separated values)

FETCh:DOWQuality:CDPNoise[16]:QCHannel[:ALL]?

Function

Queries the subtype 0 physical layer code domain power + noise measurement results for all 16 bins on Q channel.

This query returns 64 comma separated values. These represent 4 values for each of 16 bins. The 4 values returned for each bin are: Walsh code, spread factor, noise power (dB) and power (dB). See Code Domain Power + Noise Measurement Results Available Programmatically for more information about these measurement results.

There are frequently fewer than 16 bins with measurement data. For any unassigned bins (bins that don't contain measurement results), four 9.91 E+37 results are returned instead of data. This allows the query to always return 64 results regardless of how many bins contain measurement data. The FETCh:DOWQuality:CDPNoise:ICHannel:COUNt[:BIN]? command allows you to determine the total number of assigned bins (bins containing measurement results).

If the multi-measurement state is on, the results are the average of a number of code domain power measurements. Multi-measurement state is off by default. To set up multi-measurements, see SETup:DOWQuality:COUNt[:SNUMber] .

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above

Query

Range:

  • Walsh code: 0 to 15; 9.91 E+37
  • Spread Factor: 4, 8, 16; 9.91 E+37
  • Noise Power: -100.0 to 0.0 dB; 9.91 E+37
  • Power: -100.0 to 0.0 dB; 9.91 E+37

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPNoise:QCHannel?"
! Returns Walsh code, spread factor, noise power and power for bin 0.
! Then returns the same for bin 1, and repeats until the values for the last bin
! (bin 15) have been returned
! (for a total of 64 comma separated values)

FETCh:DOWQuality:CDPNoise32:ICHannel[:ALL]?

Function

Queries the subtype 2 physical layer code domain power + noise measurement results for all 32 bins on I channel.

This query returns 128 comma separated values. These represent 4 values for each of 32 bins. The 4 values returned for each bin are: Walsh code, spread factor, noise power (dB) and power (dB). See Code Domain Power + Noise Measurement Results Available Programmatically for more information about these measurement results.

There are frequently fewer than 32 bins with measurement data. For any unassigned bins (bins that don't contain measurement results), four 9.91 E+37 results are returned instead of data. This allows the query to always return 128 results regardless of how many bins contain measurement data. The FETCh:DOWQuality:CDPNoise:ICHannel:COUNt[:BIN]? command allows you to determine the total number of assigned bins (bins containing measurement results).

If the multi-measurement state is on, the results are the average of a number of code domain power measurements. Multi-measurement state is off by default. To set up multi-measurements, see SETup:DOWQuality:COUNt[:SNUMber] .

Requirements

Test Application Revision: A.06 and above, with the required feature license
Lab Application Revision: A.03 and above

Query

Range:

  • Walsh code: 0 to 31; 9.91 E+37
  • Spread Factor: 2, 4, 8, 16, 32; 9.91 E+37
  • Noise Power: -100.0 to 0.0 dB; 9.91 E+37
  • Power: -100.0 to 0.0 dB; 9.91 E+37

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPNoise32:ICHannel?"
! Returns 128 comma separated values, each four values represent
! walsh code, spread factor, noise power and power for each of 32 bins

FETCh:DOWQuality:CDPNoise32:QCHannel[:ALL]?

Function

Queries the subtype 2 physical layer code domain power + noise measurement results for all 32 bins on Q channel.

This query returns 128comma separated values. These represent 4 values for each of 32 bins. The 4 values returned for each bin are: Walsh code, spread factor, noise power (dB) and power (dB). See Code Domain Power + Noise Measurement Results Available Programmatically for more information about these measurement results.

There are frequently fewer than 32 bins with measurement data. For any unassigned bins (bins that don't contain measurement results), four 9.91 E+37 results are returned instead of data. This allows the query to always return 128 results regardless of how many bins contain measurement data. The FETCh:DOWQuality:CDPNoise:ICHannel:COUNt[:BIN]? command allows you to determine the total number of assigned bins (bins containing measurement results).

If the multi-measurement state is on, the results are the average of a number of code domain power measurements. Multi-measurement state is off by default. To set up multi-measurements, see SETup:DOWQuality:COUNt[:SNUMber] .

Requirements

Test Application Revision: A.06 and above, with the required feature license
Lab Application Revision: A.03 and above

Query

Range:

  • Walsh code: 0 to 31; 9.91 E+37
  • Spread Factor: 2, 4, 8, 16, 32; 9.91 E+37
  • Noise Power: -100.0 to 0.0 dB; 9.91 E+37
  • Power: -100.0 to 0.0 dB; 9.91 E+37

Programming Example

 
OUTPUT 714;"FETCh:DOWQuality:CDPNoise32:QCHannel?"
! Returns 128 comma separated values, each four values represent
! walsh code, spread factor, noise power and power for each of 32 bins