CALL:CELL2:OCNSource

CALL:CELL2:OCNSource

Last updated: November 8, 2010

GPIB Command Conventions

CALL:CELL2:OCNSource:LEVel[:SELected]?

Function

Queries the calculated level of the Cell 2 OCNS (orthogonal channel noise simulator) Level.

If the contribution of OCNS is calculated to be -30 dB or less, the OCNS state is turned off.

The optional [:SELected] keyword in this command specifies that the OCNS level being queried applies to the current system type.

The OCNS level is a calculated value used to balance the relative power levels of the following channels to sum to 100%:

  • Cell 2 OCNS
  • Cell 2 Pilot (PICH)
  • Cell 2 Fundamental (FCH)

Query

Range: 0 to -20 dB, NAN

Resolution: 0.01 dB

*RST Setting

NAN

Requirements

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:CELL2:OCNSOURCE:LEVEL?" !Queries the Cell 2 calculated OCNS level.

CALL:CELL2:OCNSource:STATe[:SELected]?

Function

Queries the on/off state of the Cell 2 OCNS (orthogonal channel noise simulator) Level.

If the contribution of OCNS is calculated to be -30 dB or less, the OCNS state is turned off.

The optional [:SELected] keyword in this command specifies that the OCNS on/off state being queried applies to the current system type.

The OCNS level is a calculated value used to balance the relative power levels of the following channels to sum to 100%:

  • Cell 2 OCNS
  • Cell 2 Pilot (PICH)
  • Cell 2 Fundamental (FCH)

Setting

Range: 1|0

*RST Setting

1 (on)

Requirements

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:CELL2:OCNSOURCE:STATE?" 

CALL:CELL2:OCNSource:WALSh[:SELected]

Function

Sets/queries the Walsh code used for the Cell 2 OCNS (orthogonal channel noise simulator).

The optional [:SELected] keyword in this command specifies that the OCNS Walsh code being set/queried applies to the current system type.

The Walsh codes allowed for use with this command are part of a reserved codespace that has been created by fixing other code channels to pre-determined values. Reserving this codespace eliminates the possibility of conflicts that can arise with lower walsh code sets which are used in certain radio configurations.

Setting

Range: CODE5|CODE13|CODE21|CODE29|CODE37|CODE45|CODE53|CODE61

Query

Range: 5|13|21|29|37|45|53|61

*RST Setting

CODE53

Requirements

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:CELL2:OCNSOURCE:WALSH CODE13" !Sets the OCNS channel walsh code to 13.

Related Topics


CALL:OCNSource (Cell 1 F-OCNS settings)