The setting form of this command performs two functions: (1) sets the Cell Power level and (2) turns the cell power on/off state to on. The query form returns the Cell Power level (including compensation for amplitude offset) or NAN. The optional [:SELected] keyword in this command specifies that the Cell Power level being set or queried applies to the current system type. The current system type can be changed using the CALL[:CELL]:SYSTem[:TYPE] command. Cell Power and AWGN (see CALL:AWGNoise ) are absolute power levels and make up the total forward channel RF output power. The return value for this query is not necessarily the cell power level being transmitted by the test set at the moment this command is processed by the test set. It may return a value that the test set has been requested to transmit, but that has been pended or delayed for some reason. See Troubleshooting Setting Power Levels for possible causes. To query the cell power level the test set is transmitting at the moment the command is sent, use the CALL:STATus:CELL[1]:POWer:[AMPLitude][:SELected]? command. |
|
|
|
OUTPUT 714;"CALL:CELL:POWER:SAMPLITUDE -30" !Sets the cell power state to ON and sets cell power level to -30 dBm. |
Sets/queries the cell power level (including compensation for amplitude offset). The optional [:SELected] keyword in this command specifies that the cell power level being set or queried applies to the current system type. The current system type can be changed using the CALL[:CELL]:SYSTem[:TYPE] command. Cell Power and AWGN (see CALL:AWGNoise ) are absolute power levels and make up the total forward channel RF output power. The return value for this query is not necessarily the cell power level being transmitted by the test set at the moment this command is processed by the test set. It may return a value that the test set has been requested to transmit, but that has been pended or delayed for some reason. See Troubleshooting Setting Power Levels for possible causes. To query the cell power level the test set is transmitting at the moment the command is sent, use the CALL:STATus:CELL[1]:POWer:[AMPLitude][:SELected]? command. |
|
|
|
OUTPUT 714;"CALL:CELL:POWER:AMPLITUDE -30" !Sets the cell power level -30 dBm. |
Sets/queries the cell power state. The return value for this query is not necessarily the cell power state at the moment this command is processed by the test set. This command may return a state that has been requested of the test set, but that has been pended or delayed for some reason. See Troubleshooting Setting Power Levels for possible causes. To query the cell power state of the test set at the moment, use the CALL:STATus:CELL[1]:POWer:STATe[:SELected]? command. The optional [:SELected] keyword in this command specifies that this query applies to the current system type. The current system type can be changed using the CALL[:CELL]:SYSTem[:TYPE] command. |
|
OUTPUT 714;"CALL:CELL:POWER:STATE OFF" !Turns off cell power. |