SETup:DPOWer
Last updated: May 8, 2002
Diagram Conventions
SETup:DPOWer:CONTinuous[:SELected]
|
Function
|
GSM
|
This command selects/queries the trigger state for Dynamic Power measurements in the active (that is the selected) format. |
|
GPRS
|
This command is not applicable to GPRS.
|
|
Setting |
Range:
-
Continuous trigger mode: 1|ON
-
Single trigger mode: 0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting |
The *RST value of this command depends on the format that is currently active. For example, if the GSM format is currently active, the *RST value for this command is the same value as the equivalent command containing the :GSM format identifier.
|
|
Programming Example
OUTPUT 714;"SETUP:DPOWER:CONTINUOUS:SELECTED ON" !Sets trigger mode to Continuous.
|
SETup:DPOWer:CONTinuous:GSM
|
Function
|
GSM
|
This command selects/queries the trigger state for Dynamic Power measurement in the GSM format whether or not that format is active. |
|
GPRS
|
This command is not applicable to GPRS.
|
|
Setting |
Range:
-
Continuous trigger mode: 1|ON
-
Single trigger mode: 0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting |
0 (off) |
|
Programming Example
OUTPUT 714;"SETUP:DPOWER:CONTINUOUS:GSM ON" !Sets trigger mode to Continuous.
|
SETup:DPOWer:COUNt:NUMBer[:SELected]
|
Function
|
GSM
|
This command sets/queries the number of bursts for the Dynamic Power measurement in the active (that is the selected) format.
|
|
GPRS
|
This command is not applicable to GPRS.
|
|
Setting |
Range: 1 to 999
Resolution: 1
|
|
Query
|
Range: 1 to 999
Resolution: 1
|
|
*RST Setting |
The *RST value of this command depends on the format that is currently active. For example, if the GSM format is currently active, the *RST value for this command is the same value as the equivalent command containing the :GSM format identifier.
|
|
Programming Example
OUTPUT 714;"SETUP:DPOWER:COUNT:NUMBER:SELECTED 25" !Sets the number of measurement bursts.
|
SETup:DPOWer:COUNt:NUMBer:GSM
|
Function
|
GSM
|
This command sets/queries the number of bursts for the Dynamic Power measurement in the GSM format whether or not that format is active.
|
|
GPRS
|
This command is not applicable to GPRS.
|
|
Setting |
Range: 1 to 999
Resolution: 1
|
|
Query
|
Range: 1 to 999
Resolution: 1
|
|
*RST Setting |
10 |
|
Programming Example
OUTPUT 714;"SETUP:DPOWER:COUNT:NUMBER:GSM 50" !Sets the number of measurement bursts.
|
SETup:DPOWer:EMDifference[:SELected]
|
Function
|
GSM
|
This command sets/queries the Expected Maximum Difference from Previous Measurement parameter for the Dynamic Power measurement in the active (that is the selected) format. The units dB are optional.
The Expected Maximum Difference from Previous Measurement parameter is used with the measured transmit power from the previous burst to set the maximum RF power that the base station emulator is expecting the mobile to transmit in the next burst.
The setting of this parameter does not affect the receiver Expected Power parameter. See
RFANalyzer:EXPected:POWer[:SELected]
.
|
|
GPRS
|
This command is not applicable to GPRS.
|
|
Setting |
Range: -30 dB to +30 dB
Resolution: 0.01 dB
|
|
Query
|
Range: -30 dB to +30 dB
Resolution: 0.01 dB
|
|
Programming Example
OUTPUT 714;"SETUP:DPOWER:EMDIFFERENCE:SELECTED 20" !Sets the Expected Maximum Difference
!in measurement value.
|
SETup:DPOWer:EMDifference:GSM
|
Function
|
GSM
|
This command sets/queries the Expected Maximum Difference from Previous Measurement parameter for the Dynamic Power measurement in the GSM format whether or not that format is active. The units dB are optional.
The Expected Maximum Difference from Previous Measurement parameter is used with the measured transmit power from the previous burst to set the maximum RF power that the base station emulator is expecting the mobile to transmit in the next burst.
The setting of this parameter does not affect the receiver Expected Power parameter. See
RFANalyzer:EXPected:POWer[:SELected]
.
|
|
GPRS
|
This command is not applicable to GPRS.
|
|
Setting |
Range: -30 dB to +30 dB
Resolution: 0.01 dB
|
|
Query
|
Range: -30 dB to +30 dB
Resolution: 0.01 dB
|
|
Programming Example
OUTPUT 714;"SETUP:DPOWER:EMDIFFERENCE:GSM 10" !Sets the Expected Maximum Difference
!in measurement value.
|
SETup:DPOWer:TIMeout[:STIMe][:SELected]
|
Function
|
GSM
|
This command sets/queries the Dynamic Power measurement timeout value in seconds and sets the time-out state to on for the active (that is the selected) format. The units (S|MS) are optional, if no units are specified then the default is S. |
|
GPRS
|
This command is not applicable to GPRS.
|
|
Setting |
Range: 0.1 to 999 seconds
Resolution: 0.1 seconds
|
|
Query
|
Range: 0.1 to 999 seconds
Resolution: 0.1 seconds
|
|
*RST Setting |
The *RST value of this command depends on the format that is currently active. For example, if the GSM format is currently active, the *RST value for this command is the same value as the equivalent command containing the :GSM format identifier.
|
|
Programming Example
OUTPUT 714;"SETUP:DPOWER:TIMEOUT:STIME:SELECTED 12S" !Sets the timeout state and value.
|
SETup:DPOWer:TIMeout[:STIMe]:GSM
|
Function
|
GSM
|
This command sets/queries the Dynamic Power measurement timeout value in seconds and sets the time-out state to on for the GSM format whether or not that format is active. The units (S|MS) are optional, if no units are specified then the default is S. |
|
GPRS
|
This command is not applicable to GPRS.
|
|
Setting |
Range: 0.1 to 999 seconds
Resolution: 0.1 seconds
|
|
Query
|
Range: 0.1 to 999 seconds
Resolution: 0.1 seconds
|
|
*RST Setting |
10 seconds |
|
Programming Example
OUTPUT 714;"SETUP:DPOWER:TIMEOUT:STIME:GSM 20" !Sets the timeout state and value.
|
SETup:DPOWer:TIMeout:STATe[:SELected]
|
Function
|
GSM
|
This command sets/queries the time-out state for the Dynamic Power measurement in the active (that is the selected) format. |
|
GPRS
|
This command is not applicable to GPRS.
|
|
Setting |
Range: 0|OFF|1|ON |
|
Query
|
Range: 0|1 |
|
*RST Setting |
The *RST value of this command depends on the format that is currently active. For example, if the GSM format is currently active, the *RST value for this command is the same value as the equivalent command containing the :GSM format identifier.
|
|
Programming Example
OUTPUT 714;"SETUP:DPOWER:TIMEOUT:STATE:SELECTED ON" !Sets the timeout state.
|
SETup:DPOWer:TIMeout:STATe:GSM
|
Function
|
GSM
|
This command sets/queries the time-out state for the Dynamic Power measurement in the GSM format whether or not that format is active. |
|
GPRS
|
This command is not applicable to GPRS.
|
|
Setting |
Range: 0|OFF|1|ON |
|
Query
|
Range: 0|1 |
|
*RST Setting |
0 (off) |
|
Programming Example
OUTPUT 714;"SETUP:DPOWER:TIMEOUT:STATE:GSM ON" !Sets the timeout state.
|
SETup:DPOWer:TIMeout:TIMe[:SELected]
|
Function
|
GSM
|
This command sets/queries the time-out value in seconds that is used for the Dynamic Power measurement for the active (that is the selected) format. The time-out state must be ON. The units (S|MS) are optional, if no units are specified then the default is S. |
|
GPRS
|
This command is not applicable to GPRS.
|
|
Setting |
Range: 0.1 to 999 seconds
Resolution: 0.1 seconds
|
|
Query
|
Range: 0.1 to 999 seconds
Resolution: 0.1 seconds
|
|
*RST Setting |
The *RST value of this command depends on the format that is currently active. For example, if the GSM format is currently active, the *RST value for this command is the same value as the equivalent command containing the :GSM format identifier.
|
|
Programming Example
OUTPUT 714;"SETUP:DPOWER:TIMEOUT:TIME:SELECTED 15" !Sets the timeout value.
|
SETup:DPOWer:TIMeout:TIMe:GSM
|
Function
|
GSM
|
This command sets/queries the time-out value in seconds that is used for the Dynamic Power measurements when the time-out state is ON for the GSM format whether or not that format is active. The units (S|MS) are optional, if no units are specified then the default is S. |
|
GPRS
|
This command is not applicable to GPRS.
|
|
Setting |
Range: 0.1 to 999 seconds
Resolution: 0.1 seconds
|
|
Query
|
Range: 0.1 to 999 seconds
Resolution: 0.1 seconds
|
|
*RST Setting |
10 seconds |
|
Programming Example
OUTPUT 714;"SETUP:DPOWER:TIMEOUT:TIME:GSM 10S" !Sets the timeout value.
|
Back to Top
|