Last Updated: August 29, 2007
These commands set up channels for the W-CDMA Cal Application.
For more information on the conventions used in the programming examples click here.
Sets/queries the UTRA DL channel. For more information see Downlink Channel UARFCN.
Setting Range:
412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687, 1007, 1012, 1032, 1037, 1062, 1087
1162 to 1513
1537 to 1738
1887, 1912, 1937, 1962, 1987, 2012, 2037, 2062, 2087
2237 to 2563
2587, 2612, 2637, 2662, 2687, 2712, 2737, 2762, 2787, 2812, 2837, 2862, 2887, 2912
2937 to 3088
3112 to 3388
3412, 3437, 3462, 3487, 3512, 3537, 3562, 3587, 3612,3637, 3662, 3687
3712 to 3812
4357 to 4458
4387 to 4413
9237 to 9387
9662 to 9938
10562 to 10838
Query Range:
412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687, 1007, 1012, 1032, 1037, 1062, 1087
1162 to 1513
1537 to 1738
1887, 1912, 1937, 1962, 1987, 2012, 2037, 2062, 2087
2237 to 2563
2587, 2612, 2637, 2662, 2687, 2712, 2737, 2762, 2787, 2812, 2837, 2862, 2887, 2912
2937 to 3088
3112 to 3388
3412, 3437, 3462, 3487, 3512, 3537, 3562, 3587, 3612,3637, 3662, 3687
3712 to 3812
4357 to 4458
4387 to 4413
9237 to 9387
9662 to 9938
10562 to 10838
*RST Setting: 10700
Test Set Requirements: E6601A WCTS Program Version A.02 and above; A.05 added Band VII, X, and XI UARFCNs.
Example:
' Set the UTRA DL channel to 10700.
TestSet.WriteString("TRANsceiver:CHANnel:DOWNlink:FDD 10700")
Sets/queries the UTRA FDD uplink separation parameter. This specifies the separation in MHz between the downlink channel and the uplink channel when the RFANalyzer:CONTrol:FREQuency:AUTO[:SELected][?] command is set to ON.
When RFANalyzer:CONTrol:FREQuency:AUTO[:SELected][?] is set to ON, the TRANsceiver:CHANnel:UPLink:SEParation:FDD[?] command is coupled to the value of the RFGenerator:FREQuency:WCALibration[?] command regardless of the setting of the RFGenerator:CONTrol:FREQuency:AUTO:WCALibration[?].
If you change the UTRA FDD uplink separation value to cause the uplink channel to be invalid, you will receive an invalid channel message.
For more information see Uplink Channel UARFCN.
Setting Range: MHZ45 | MHZ48 | MHZ80 | MHZ95 | MHZ120 | MHZ190 | MHZ400
Query Range: MHZ45 | MHZ48 | MHZ80 | MHZ95 | MHZ120 | MHZ190 | MHZ400
*RST Setting: MHZ190
Test Set Requirements: E6601A WCTS Program Version A.02 and above; A.05 added MHZ48 and MHZ120
Example:
' Set the UTRA FDD uplink separation to 400 MHz.
TestSet.WriteString("TRANsceiver:CHANnel:UPLink:SEParation:FDD MHZ400")