Last updated: November 17, 2008
Sets/queries the alternate offset of the test 3 since the outer emission powers alternate limit are changed with the offset when the Test Case Setup is set to Test 3. See TX Spurious Emissions Measurement Parameters , "Test3 Alternate Offset/Test3 Second Alternate Offset" |
|
Requirements | Test Application Revision: A.09 and above |
3.47 | |
OUTPUT 714;"SETup:CTXSpurious:ALTernate:OFFSet:TEST3 3.47" !Sets alternate offset of the test 3 to 3.47 MHz. |
Sets/queries the second alternate offset of the test 3 since the outer emission powers alternate limit are changed with the offset when the Test Case Setup is set to Test 3. See TX Spurious Emissions Measurement Parameters , "Test3 Alternate Offset/Test3 Second Alternate Offset" |
|
Requirements | Lab Application Revision: C.00.00 and above |
6.50 MHz | |
OUTPUT 714;"SETup:CTXSpurious:ALTernate2:OFFSet:TEST3 3.5" !Sets the second alternate offset of the test 3 to 3.5 MHz. |
Sets/queries the trigger arm state for the tx spurious emissions measurement. The trigger arm state determines whether the tx spurious emissions measurement will be made once then stop (0|OFF (single)), or automatically re-arm upon completion of one measurement and repeat the process (1|ON (continuous)). See TX Spurious Emissions Measurement Parameters , "Trigger Arm." |
|
Requirements |
Test Application Revision: A.01.20 and above Lab Application Revision: A.01 and above |
OUTPUT 714;"SETup:CTXSpurious:CONTinuous OFF" !Sets measurement to single trigger mode. |
The setting form of this command performs two functions: (1) sets the number of tx spurious emissions measurements to be made in a multi-measurement, and (2) sets the multi-measurement STATe command to 1 (on). The query form returns the number of tx spurious emissions multi-measurements to be made when multi-measurement state is ON. See TX Spurious Emissions Measurement Parameters , "Multi-Measurement Count." |
|
Requirements |
Test Application Revision: A.01.20 and above Lab Application Revision: A.01 and above |
Off (10 when STATe = On) | |
OUTPUT 714;"SETup:CTXSpurious:COUNt 5" !Turns on multi-measurements and sets the number of measurements to 5. |
Sets/queries the number of tx spurious emissions measurements to be made when the multi-measurement state is ON. See TX Spurious Emissions Measurement Parameters , "Multi-Measurement Count." |
|
Requirements |
Test Application Revision: A.01.20 and above Lab Application Revision: A.01 and above |
10 | |
OUTPUT 714;"SETup:CTXSpurious:COUNt:NUMBer 5" !Sets the number of tx spurious emissions multi-measurements to 5. |
Sets/queries the tx spurious emissions multi-measurement state. See TX Spurious Emissions Measurement Parameters , "Multi-Measurement Count." |
|
Requirements |
Test Application Revision: A.01.20 and above Lab Application Revision: A.01 and above |
OUTPUT 714;"SETup:CTXSpurious:COUNt:STATe ON" ! Turns on tx spurious emissions multi-measurements. |
Sets/queries the mask control. ON (1) sets the mask limits to the values specified in C.S0033. OFF (0) allows you to set arbitrary limits (see SETup:CTXSpurious:MASK:MANual:ADJacent[:LIMit] and SETup:CTXSpurious:MASK:MANual:ALTernate[:LIMit] ). See TX Spurious Emissions Measurement Parameters , "Mask Control." |
|
Requirements |
Test Application Revision: A.01.20 and above Lab Application Revision: A.01 and above |
OUTPUT 714;"SETup:CTXSpurious:MASK:AUTO ON" |
Sets/queries the tx spurious emissions manually set measurement limit mask. This limit is activated when SETup:CTXSpurious:MASK:AUTO is set to OFF (0). See TX Spurious Emissions Measurement Parameters , "Adjacent Limit." |
|
Requirements |
Test Application Revision: A.01.20 and above Lab Application Revision: A.01 and above |
OUTPUT 714;"SETup:CTXSpurious:MASK:MANual:ADJacent -45" |
Sets/queries the tx spurious emissions manually set measurement limit mask. This limit is activated when SETup:CTXSpurious:MASK:AUTO is set to OFF (0). See TX Spurious Emissions Measurement Parameters , "Alternate Limit." |
|
Requirements |
Test Application Revision: A.01.20 and above Lab Application Revision: A.01 and above |
Range/Resolution: Same as setting. | |
-50 dBc | |
OUTPUT 714;"SETup:CTXSpurious:MASK:MANual:ALTernate -55". |
Sets/queries the tx spurious emissions manually set measurement limit mask of the test case 2 . This limit is activated when SETup:CTXSpurious:TCASe is set to Test 2 and SETup:CTXSpurious:MASK:AUTO is set to OFF (0). See TX Spurious Emissions Measurement Parameters , "TestX Adjacent Limit." |
|
Requirements | Test Application Revision: A.09 and above |
Range/Resolution: Same as setting. | |
6 dBm/1MHz | |
OUTPUT 714;"SETup:CTXSpurious:MASK:MANual:ADJacent:TEST2 6" ! Sets the Tx Spurious Emissions measurement limit mask of the test case 2 to 6 dBm/1MHz |
Sets/queries the tx spurious emissions manually set measurement limit mask of the test case 2 . This limit is activated when SETup:CTXSpurious:TCASe is set to Test 2 and SETup:CTXSpurious:MASK:AUTO is set to OFF (0). See TX Spurious Emissions Measurement Parameters , "TestX Alternate Limit." |
|
Requirements | Test Application Revision: A.09 and above |
Range/Resolution: Same as setting. | |
-13 dBm/1MHz | |
OUTPUT 714;"SETup:CTXSpurious:MASK:MANual:ADJacent:TEST2 -13" ! Sets the Tx Spurious Emissions measurement limit mask of the test case 2 to -13 dBm/1MHz |
Sets/queries the tx spurious emissions manually set measurement limit mask of the test case 3 . This limit is activated when SETup:CTXSpurious:TCASe is set to Test 3 and SETup:CTXSpurious:MASK:AUTO is set to OFF (0). See TX Spurious Emissions Measurement Parameters , "TestX Adjacent Limit." |
|
Requirements | Test Application Revision: A.09 and above |
Range/Resolution: Same as setting. | |
-14 dBm/30kHz | |
OUTPUT 714;"SETup:CTXSpurious:MASK:MANual:ADJacent:TEST3 6" ! Sets the Tx Spurious Emissions measurement limit mask of the test case 3 to 6 |
Sets/queries the tx spurious emissions manually set measurement limit mask of the test case 3 . This limit is activated when SETup:CTXSpurious:TCASe is set to Test 3 and SETup:CTXSpurious:MASK:AUTO is set to OFF (0). See TX Spurious Emissions Measurement Parameters , "TestX Alternate Limit." |
|
Requirements | Test Application Revision: A.09 and above |
Range/Resolution: Same as setting. | |
-25.55 dBm/30kHz | |
OUTPUT 714;"SETup:CTXSpurious:MASK:MANual:ADJacent:TEST3 -13" ! Sets the Tx Spurious Emissions measurement limit mask of the test case 3 to -13 |
Sets/queries the second manually set measurement limit mask of the test case 3 of the tx spurious emissions measurement. This limit is activated when SETup:CTXSpurious:TCASe is set to Test 3 and SETup:CTXSpurious:MASK:AUTO is set to OFF (0). See TX Spurious Emissions Measurement Parameters , "Test3 Second Alternate Limit." |
|
Requirements | Lab Application Revision: C.00.00 and above |
Range/Resolution: Same as setting. | |
-25.55 dBm/30kHz | |
OUTPUT 714;"SETup:CTXSpurious:MASK:MANual:ADJacent:TEST3 -13" ! Sets the Tx Spurious Emissions measurement limit mask of the test case 3 to -13 |
Sets/queries the tx spurious emissions test case that will be used. See TX Spurious Emissions Measurement Parameters , "Test Case Setup" |
|
Requirements | Test Application Revision: A.09 and above |
TEST1 | TEST2 | TEST3 | |
Range: Same as setting. | |
TEST1 | |
OUTPUT 714;"SETup:CTXSpurious:TCASe TEST1" ! Sets the Tx Spurious Emissions test case to Test 1 |
The setting form of this command performs two functions: (1) sets the tx spurious emissions measurement's timeout (see Measurement Timeouts ) value, and (2) sets the tx spurious emissions measurement's timeout STATe to 1 (on). The query form returns the tx spurious emissions measurement's timeout value. See TX Spurious Emissions Measurement Parameters , "Timeout Time/State." |
|
Requirements |
Test Application Revision: A.01.20 and above Lab Application Revision: A.01 and above |
OUTPUT 714;"SETup:CTXSpurious:TIMeout 5" !Sets timeout state to ON and sets the timeout time to 5 seconds. |
Sets/queries the tx spurious emissions measurement's timeout (see Measurement Timeouts ) state. See TX Spurious Emissions Measurement Parameters , "Timeout Time/State." |
|
Requirements |
Test Application Revision: A.01.20 and above Lab Application Revision: A.01 and above |
OUTPUT 714;"SETup:CTXSpurious:TIMeout:STATe ON" |
Sets/queries the tx spurious emissions measurement's timeout (see Measurement Timeouts ) setting to be used when the timeout state is set to ON. See TX Spurious Emissions Measurement Parameters , "Timeout Time/State." |
|
Requirements |
Test Application Revision: A.01.20 and above Lab Application Revision: A.01 and above |
OUTPUT 714;"SETup:CTXSpurious:TIMeout:TIME 5" |