Function |
Set/Queries the PEMaxCommon parameter. See OtherRATNeighborList Message Parameters |
Same as setting | |
23 dBm | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:COMMon:PEMax 23" ! Set the PEMaxCommon to 23. |
Function |
Set/Queries the RxLevMinEUTRACommon parameter. See OtherRATNeighborList Message Parameters |
Same as setting | |
-104 dBm | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:COMMon:RLMinimum -104" ! Set the RxLevMinEUTRACommon to -104. |
Function |
Set/Queries the RxLevMinEUTRAOffsetCommon Included parameter. See OtherRATNeighborList Message Parameters |
1|ON|0|OFF | |
1|0 | |
0|OFF | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:COMMon:RLMinimum:OFFSet:INCLuded Off" ! Set the RxLevMinEUTRAOffsetCommon Included to Off. |
Function |
Set/Queries the RxLevMinEUTRAOffsetCommon parameter. See OtherRATNeighborList Message Parameters . |
Same as setting | |
1 | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:COMMon:RLMinimum:OFFSet 1" ! Set the RxLevMinEUTRAOffsetCommon to 1. |
Function |
Sets/Queries the Number of EUTRA Frequencies . |
Same as setting | |
1 | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:FREQuency:NUMBer 1" ! Set the Number of EUTRA Frequencies to 1. |
Function |
Sets/Queries E-UTRAN to eHRPD Optimized Handoff State . |
1|0 | |
0|OFF | |
Requirements | Lab Application Revision: F.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:HANDoff:OPTimized:STATe Off"
! Set the
|
Function |
Set/Queries the Minimum Measurement Backoff Timer parameter. See OtherRATNeighborList Message Parameters . |
Same as setting | |
1 | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:MBOTimer:MINimum 1" ! Set the Minimum Measurement Backoff Timer to 1. |
Function |
Set/Queries the Maximum Measurement Backoff Timer parameter. See OtherRATNeighborList Message Parameters . |
Same as setting | |
5 | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:MBOTimer:MAXimum 5" ! Set the Maximum Measurement Backoff Timer to 5. |
Function |
Set/Queries the Maximum Reselection Timer Included parameter. See OtherRATNeighborList Message Parameters . |
1|0 | |
0|OFF | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:MRTimer:INCLuded Off" ! Set the Maximum Reselection Timer Included to Off. |
Function |
Set/Queries the Maximum Reselection Timer parameter. See OtherRATNeighborList Message Parameters . |
0 ~ 15 | |
3 | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:MRTimer 3" ! Set the Maximum Reselection Timer to 3. |
Sets/queries Per EARFCN Parameters Included . | |
Same as setting. | |
OFF | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:PEParameters:INCLuded Off" |
Sets/queries PLMN ID Included . | |
Same as setting. | |
OFF | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:PLMNetwork:INCLuded Off" |
Function |
Set/Queries Pre-registration via E-UTRAN State . |
1|0 | |
0|OFF | |
Requirements | Lab Application Revision: F.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:PRERegister:STATe Off"
! Set the
|
Function |
Set/Queries the Priority Included parameter. See OtherRATNeighborList Message Parameters . |
1|0 | |
0|OFF | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:PRIority:INCLuded Off" ! Set the Priority Included to Off. |
Function |
Set/Queries the Search Back-off Timer Included parameter. See OtherRATNeighborList Message Parameters . |
1|0 | |
1|ON | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:SBOTimer:INCLuded On" ! Set the Search Back-off Timer Included to On. |
Function |
Set/Queries the Serving Cell Priority parameter. See OtherRATNeighborList Message Parameters . |
0 ~ 7 | |
3 | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:SERVing:PRIority 3" ! Set the Serving Cell Priority to 3. |
Function |
Set/Queries the Serving Cell Threshold parameter. See OtherRATNeighborList Message Parameters . |
Same as setting | |
0.0 dB | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:SERVing:THReshold 0" ! Set the Serving Cell Threshold to 0 dB. |
Function |
Set/Queries the EARFCN 1/2 . |
0 ~ 65535 | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:EARFcn 5230" ! Set the EARFCN 1 to 5230. |
Function |
Set/Queries the EARFCN 1/2 Measurement Bandwidth . |
MBW6 | MBW15 | MBW25 | MBW50 | MBW75 | MBW100 | |
MBW6 | MBW15 | MBW25 | MBW50 | MBW75 | MBW100 | |
MBW15 | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:MBWidth MBW15" ! Set the EARFCN 1 Measurement Bandwidth to MBW15. |
Sets/queries EARFCN 1/2 PEMax . | |
Same as setting. | |
23 (dBm) | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:PEMax 2" |
Sets/queries EARFCN 1/2 PLMN ID . | |
Same as setting. | |
0, 0, Auto | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:PLMNetwork:IDENtity 0,0,Auto" |
Sets/queries EARFCN 1/2 Number of PLMN ID . | |
Same as setting. | |
1 | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:PLMNetwork:NUMBer 2" |
Sets/queries EARFCN 1/2 PLMN Same as Previous Channel . | |
Same as setting. | |
False | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:PLMNetwork:SAPChannel True" |
Function |
Set/Queries the EARFCN 1/2 Priority . |
0 ~ 7 | |
0 ~ 7 | |
3 | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:PRIority 3" ! Set the EARFCN 1 Priority to 3. |
Sets/queries EARFCN 1/2 RxLevMinEUTRA . | |
Same as setting. | |
-104 (dBm) | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:RLMinimum -104" |
Sets/queries EARFCN 1/2 RxLevMinEUTRAOffset . | |
Same as setting. | |
1 | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:RLMinimum:OFFSet 2" |
Sets/queries EARFCN 1/2 RxLevMinEUTRAOffset Included . | |
Same as setting. | |
OFF | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:RLMinimum:OFFSet:INCLuded Off" |
Function |
Set/Queries the EARFCN 1/2 ThreshX . |
Same as setting | |
30 (dBm) | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:EUTRa:THReshold 30" ! Set the EARFCN 1 ThreshX . parameter to 30 dB |
Function |
Set/Queries the Partial HSGW Context Available State . |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:HSGW:PCONtext:STATe Off" ! Set the Partial HSGW Context Available State parameter to Off. |
Function |
Set/Queries the Other RAT Available State parameter. See QuickConfig Message Parameters . |
1|0 | |
0|OFF | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:ORAT:STATe Off" ! Set the Other RAT Available State to Off. |
Function |
Set/Queries the Other RAT TX Cycle parameter, in unit of Control Channel Cycle. See QuickConfig Message Parameters . |
CYCLe2 | CYCLe3 | CYCLe6 | CYCLe10 | CYCLe14 | CYCLe24 | CYCLe40 | CYCLe64 |
|
CYCL2 | CYCL3 | CYCL6 | CYCL10 | CYCL14 | CYCL24 |CYCL40 | CYCL64 | |
CYCLe10 | |
Requirements | Lab Application Revision: E.00.00 and above |
OUTPUT 714;"CALL:IRAT:ORAT:TXCycle CYCLe10" ! Set the Other RAT TX Cycle: . to 10. |