Function |
Queries the F-FCH EIB test results. It is returned in a comma separated list in the order of Good Frames Matched, Good Frames Not Matched, Good Frames Not Received, Bad Frames Matched, Bad Frames Not Matched, Bad Frames Not Received. See MS Reported Erasure Indicator Bit (EIB) Information for details. |
Requirements | Lab Application Revision: B.02 and above |
OUTPUT 714;"CALL:FPControl:EIBCount?" |
This command clears all of the F-FCH EIB counters to zeroes. See To Clear the MS Reported Erasure Indicator Bit (EIB) Information for details. |
|
Requirements | Lab Application Revision: B.02 and above |
OUTPUT 714;"CALL:FPControl:EIBCount:CLEar" !Clears all of the EIB counters to zeroes. |
This command starts to increment the F-FCH EIB counters. See To Start/Stop EIB Counters for details. |
|
Requirements | Lab Application Revision: B.02 and above |
OUTPUT 714;"CALL:FPControl:EIBCount:STARt" !Starts to increment the F-FCH EIB counters. |
Requirements | Lab Application Revision: B.02 and above |
OUTPUT 714;"CALL:FPControl:EIBCount:STOP" !Stops incrementing the F-FCH EIB counters. |
Sets/queries the target frame error rate on the F-FCH for the outer loop power control. See FPC F-FCH Target FER for details. |
|
Range: 0.2 to 30 (in percent) |
|
Range: 0.2, 0.5 - 10 (in 0.5 increment), 11 - 15 (in 1.0 increment), 18 - 30 (in 3.0 increment) |
|
Requirements | Lab Application Revision: B.02 and above |
OUTPUT 714;"CALL:FPControl:FCHannel:FERate:TARGet" !Sets target FER for outer loop power control |
Sets/queries the upper limit of the F-FCH level (Ec/Ior) that the test set can be adjusted to according to the forward power control by the MS. See Maximum F-FCH Level for details. |
|
Requirements | Lab Application Revision: B.02 and above |
OUTPUT 714;"CALL:FPControl:FCHannel:LEVel:MAXimum -10" !Sets the upper limt of the F-FCH level to -10 dB !according to the forward power control by MS. |
Sets/queries the initial F-FCH outer loop Eb/Nt setpoint in dB. See FPC F-FCH Initial Setpoint (dB) for details. |
|
Requirements | Lab Application Revision: B.02 and above |
OUTPUT 714;"CALL:FPControl:FCHannel:SETPoint:INITial 10" !Sets the initial F-FCH outer loop Eb/Nt setpoint to 10 dB. |
Sets/queries the maximum F-FCH outer loop Eb/Nt setpoint in dB. See FPC F-FCH Maximum Setpoint (dB) for details. |
|
Requirements | Lab Application Revision: B.02 and above |
OUTPUT 714;"CALL:FPControl:FCHannel:SETPoint:MAXimum 10" !Sets the maximum F-FCH outer loop Eb/Nt setpoint to 10 dB. |
Sets/queries the minimum F-FCH outer loop Eb/Nt setpoint in dB. See FPC F-FCH Minimum Setpoint (dB) for details. |
|
Requirements | Lab Application Revision: B.02 and above |
OUTPUT 714;"CALL:FPControl:FCHannel:SETPoint:MINimum 10" !Sets the minimum F-FCH outer loop Eb/Nt setpoint to 10 dB. |
Sets/queries forward power control (FPC) mode to be used by the mobile station. See FPC Mode for details. |
|
Requirements | Lab Application Revision: B.02 and above, D.01.00 Added [:NORMal] |
OUTPUT 714;"CALL:FPControl:MODE MODE000" !Sets to use the FPC mode 000. |
Sets/queries the power step size for forward power control (FPC) under RC3, RC4 and RC5. It is used to tells the test set how much to increase or decrease its output power in response to a power control bit from the mobile station. See Forward Power Control Step Size . |
|
Range: DB1|DBHalf|DBQuarter |
|
DBH (0.5 dB) | |
Requirements | Lab Application Revision: B.02 and above, D.01.00 Added [:NORMal] |
OUTPUT 714;"CALL:FPControl:STEP DB1" !Sets FPC step size to 1 dB. |
Function |
Queries the outer loop Eb/Nt setpoint of the F-FCH last retrieved from the moible station by sending the CALL[:CELL]:FPControl:OLReport:REQuest . See MS Reported F-FCH Current Setpoint for detilas. |
Requirements | Lab Application Revision: B.02 and above |
OUTPUT 714;"CALL:FPControl:OLReport:FCHannel:SETPoint:CURRent?" !Queries the outer loop Eb/Nt setpoint of the F-FCH !last retrieved from the moible station. |
This command sends a request to the mobile station for reporting outer loop power control results which can then be queried with CALL[:CELL]:FPControl:OLReport:FCHannel:SETPoint:CURRent? . See To Request an Outer Loop Report from the MS for details. |
|
Requirements | Lab Application Revision: B.02 and above |
OUTPUT 714;"CALL:FPControl:OLReport:REQuest" !Requests the outer loop report from mobile station. |
OUTPUT 714;"CALL:FPControl:SLOW:MODE MODE000" !Sets to use the FPC mode 000. |
Sets/queries the power step size for forward power control (FPC) under RC6. See Forward Power Control Step Size <RC6> . |
|
Range: DB1|DBHalf|DBQuarter|DB1Point5|DB2 |
|
DBH (0.5 dB) | |
OUTPUT 714;"CALL:FPControl:SLOW:STEP DB1" !Sets FPC step size to 1 dB. |