Last updated: October 30, 2013
Sets/queries ATIM Indicator . | |
Off | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:ATIMessage:INDicator Off" |
Sets/queries ATIM Cycle Index . | |
Same as setting. | |
1 | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:ATIMessage:CYCLe 2" |
Sets/queries PEMaxCommon . | |
Same as setting. | |
23 (dBm) | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:COMMon:PEMax 2" |
Sets/queries RxLevMinEUTRACommon . | |
Same as setting. | |
-104 (dBm) | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:COMMon:RLMinimum -104" |
Sets/queries RxLevMinEUTRAOffsetCommon . | |
Same as setting. | |
1 | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:COMMon:RLMinimum:OFFSet 2" |
Sets/queries RxLevMinEUTRAOffsetCommon Included . | |
Same as setting. | |
OFF | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:COMMon:RLMinimum:OFFSet:INCLuded Off" |
Sets/queries CS Fallback From E-UTRAN State . | |
Off | |
Requirements | Lab Application Revision: G.00.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:CSFBack:STATe OFF" !Disable CS fallback from E-UTRAN to CDMA2000 system. |
Sets/queries EARFCN 1/2 . | |
Same as setting. | |
5230 ( EARFCN 1). 5790 ( EARFCN 2) | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:EARFcn 2" |
Sets/queries EARFCN 1/2 Measurement Bandwidth . | |
Same as setting. | |
MBW15 | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:MBWidth MBW6" |
Sets/queries EARFCN 1/2 PEMax . | |
Same as setting. | |
23 (dBm) | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:PEMax 2" |
Sets/queries EARFCN 1/2 PLMN ID . | |
Same as setting. | |
0, 0, Auto | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:PLMNetwork 0,0,Auto" |
Sets/queries EARFCN 1/2 Number of PLMN ID . | |
Same as setting. | |
1 | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:PLMNetwork:NUMBer 2" |
Sets/queries EARFCN 1/2 PLMN Same as Previous Channel . | |
Same as setting. | |
False | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:PLMNetwork:SAPChannel True" |
Sets/queries EARFCN 1/2 Priority . | |
Same as setting. | |
3 | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:PRIority 2" |
Sets/queries EARFCN 1/2 RxLevMinEUTRA . | |
Same as setting. | |
-104 (dBm) | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:RLMinimum -104" |
Sets/queries EARFCN 1/2 RxLevMinEUTRAOffset . | |
Same as setting. | |
1 | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:RLMinimum:OFFSet 2" |
Sets/queries EARFCN 1/2 RxLevMinEUTRAOffset Included . | |
Same as setting. | |
OFF | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:RLMinimum:OFFSet:INCLuded Off" |
Sets/queries EARFCN 1/2 ThreshX . | |
Same as setting. | |
30 (dBm) | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:THReshold 2" |
Sets/queries Number of EUTRA Frequencies . | |
Same as setting. | |
1 | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:FREQuency:NUMBer 2" |
Sets/queries Maximum Measurement Backoff Timer . | |
Same as setting. | |
5 | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:MBOTimer:MAXimum 8" |
Sets/queries Minimum Measurement Backoff Timer . | |
Same as setting. | |
1 | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:MBOTimer:MINimum 2" |
Sets/queries Maximum Reselection Timer . | |
Same as setting. | |
3 | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:MRTimer 2" |
Sets/queries Maximum Reselection Timer Included . | |
Same as setting. | |
OFF | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:MRTimer:INCLuded Off" |
Sets/queries Per EARFCN Parameters Included . | |
Same as setting. | |
OFF | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:PEParameters:INCLuded Off" |
Sets/queries PLMN ID Included . | |
Same as setting. | |
OFF | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:PLMNetwork:INCLuded Off" |
Sets/queries Priority Included . | |
Same as setting. | |
OFF | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:PRIority:INCLuded Off" |
Sets/queries Search Back-off Timer Included . | |
Same as setting. | |
OFF | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:SBOTimer:INCLuded Off" |
Sets/queries Serving Cell Priority . | |
Same as setting. | |
3 | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:SERVing:PRIority 2" !Set the Serving Cell Priority to 3. |
Sets/queries Serving Cell Threshold . | |
Same as setting. | |
0.0 (dB) | |
Requirements | Lab Application Revision: F.01.00 and above |
OUTPUT 714;"CALL:CELL:IRAT:EUTRa:SERVing:THReshold -31.5" |