Testing 4.3.3 Reverse Pilot Channel to Code Channel Phase Tolerance
Definition: This test measures the permissible error in RF phase between the radiated Reverse Pilot Channel and the other code channels when operating with Radio Configurations 3 through 6.
You can perform the above two tests with the following test procedure. It assumes that the mobile station supports Band Class 1 (US PCS) and Radio Configuration 3 or above. Unless otherwise stated, leave all parameter settings to the defaults. For details on performing the steps below, see the General Procedure above.
Both tests can be made only when the call is established with radio configuration ((Fwd3, Rvs3), or above) selected.
-
- Connect the mobile station's antenna output to the test set's front panel RF IN/OUT connector and power them on.
- Press the blue SHIFT key and then the green Preset key to full reset the test set.
- Establish a call with the following parameter settings (some settings need change as specified for other tests).
-
- Press CALL SETUP to access Call Parms and Call Control menus.
- Set
Cell Band
( F8 on the Call Parms 1 of 3
) to US PCS
.
- Set
Radio Config
( F11 on the Call Parms 1 of 3
) to (Fwd3, Rvs3)
.
- Select FCH Service Option Setup ( F12 )
(Call Parms 1 of 3)
, set Service Option for Fwd3, Rvs3
to SO2
.
- Set
Cell Power
(Î or ) to -55 dBm/1.23 MHz
( F7 on the Call Parms 1 of 3
).
- Press
Originate Call
( F3 ) to initiate a call. Verify that the Connected
is in the Active Cell status
field.
- Press the Measurement selection key, select the
Code Channel Time/Phase Error
measurement.
- Press the
Code Time/Phase Error
Setup ( F1 ) key to access the Code Time/Phase Error
Setup menu and set the measurement parameters as needed, then press the Close Menu
( F6 ) key.
- Set the Time Limit ( F3 ) to 10 ns, or as needed.
- Set the
Phase Limit
( F4 ) to 0.05 rad, or as needed.
- If
single
is selected in the Trigger Arm
field, press the START SINGLE key to trigger each measurement. If the Trigger Arm
is set to Continuous
, you can skip this step.
- A typical display is shown below. Observe the pass/fail result.
- To display the numeric results for a code channel, press the
Marker Position
( F2 ) and turn the knob to position the marker to the bar.
- If desired, after finishing the measurements, turn the measurement off by pressing the Measurement selection key, selecting
Code Channel Time/Phase Error
, then Close Measurement
( F4 ).