Queries the waveform quality/code domain power measurements. Measurement results are returned in the following order: integrity, rho, frequency error, time error, carrier feedthrough, phase error, magnitude error, and error vector magnitude (EVM). If the multi-measurement state is on, each result represents the average of a number of waveform quality/code domain power measurements. Multi-measurement state, by default, is off. To set up multi-measurements, see SETup:WQUality:COUNt[:SNUMber] . |
|
OUTPUT 714;"FETCH:WQUALITY:ALL?" !Returns integrity, rho, frequency error, time error, carrier feedthrough, phase error, !magnitude error, EVM. |
Queries the intermediate count of measurements completed in a multi-measurement. |
|
OUTPUT 714;"FETCH:WQUALITY:ICOUNT?" |
Queries the EVM of the 1536 chips during the single power control group of the waveform quality measurement. |
|
|
|
Test Application Revision: B.14 and above | |
OUTPUT 714;"FETCh:WQUality:EVM:TRACe?" Queries the EVM of the 1536 chips during the single power control group. |
This command provides a direct method for obtaining reverse supplemental channel one only total code domain power and total code domain power relative to the reverse pilot channel, without the need for specifying a bin number. This query returns 7 comma separated values. See Obtaining code channel information programmatically by code channel name for more information. |
|
I channel or Q channel: 0=I, 1=Q; 9.91 E +37 Normalized Total Code Domain Power Relative to Pilot(relative to total reverse channel pilot): -100.0 to +100.0 dB; 9.91 E+37 |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER64:ACKCHANNEL1?" Queries the reverse ACK channel1 code domain power information. |
This command provides a direct method for obtaining reverse supplemental channel one only total code domain power and total code domain power relative to the reverse pilot channel, without the need for specifying a bin number. This query returns 7 comma separated values. See Obtaining code channel information programmatically by code channel name for more information. |
|
I channel or Q channel: 0=I, 1=Q; 9.91 E +37 Normalized Total Code Domain Power Relative to Pilot(relative to total reverse channel pilot): -100.0 to +100.0 dB; 9.91 E+37 |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER64:ACKCHANNEL2?" Queries the reverse ACK channel2 code domain power information. |
This command provides a direct method for obtaining reverse supplemental channel one only total code domain power and total code domain power relative to the reverse pilot channel, without the need for specifying a bin number. This query returns 7 comma separated values. See Obtaining code channel information programmatically by code channel name for more information. |
|
I channel or Q channel: 0=I, 1=Q; 9.91 E +37 Normalized Total Code Domain Power Relative to Pilot(relative to total reverse channel pilot): -100.0 to +100.0 dB; 9.91 E+37 |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER64:ACKCHANNEL3?" Queries the reverse ACK channel3 code domain power information. |
This command provides a method for obtaining reverse pilot channel only code domain power, without the need for specifying a bin number. This query returns 6 comma separated values.
See
Obtaining code channel information programmatically by code channel name
for more information. |
|
I channel or Q channel: 0=I, 1=Q; 9.91 E +37 |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER:PILOT?" Queries the reverse pilot code domain power information. |
This command provides a method for obtaining reverse pilot channel only code domain power, without the need for specifying a bin number. This query returns 7 comma separated values. See Obtaining code channel information programmatically by code channel name for more information. |
|
I channel or Q channel: 0=I, 1=Q; 9.91 E +37 Normalized Total Code Domain Power Relative to Pilot(relative to total reverse channel pilot): -100.0 to +100.0 dB; 9.91 E+37 |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER64:PILOT?" Queries the reverse pilot code domain power information. |
This command provides a direct method for obtaining reverse dedicated control channel only code domain power and code domain power relative to the reverse pilot channel, without the need for specifying a bin number. This query returns 6 comma separated values.
See
Obtaining code channel information programmatically by code channel name
for more information. |
|
I channel or Q channel: 0=I, 1=Q; 9.91 E +37 |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER:CCHANNEL:DEDICATED?" Queries the reverse dedicated control channel code domain power information. |
This command provides a direct method for obtaining reverse fundamental channel only code domain power and code domain power relative to the reverse pilot channel, without the need for specifying a bin number. This query returns 6 comma separated values.
See
Obtaining code channel information programmatically by code channel name
for more information. |
|
I channel or Q channel: 0=I, 1=Q; 9.91 E +37 |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER:FCHANNEL?" Queries the reverse fundamental channel code domain power information. |
This command provides a direct method for obtaining reverse fundamental channel only code domain power and code domain power relative to the reverse pilot channel, without the need for specifying a bin number. This query returns 7 comma separated values.
See
Obtaining code channel information programmatically by code channel name
for more information. |
|
I channel or Q channel: 0=I, 1=Q; 9.91 E +37 Normalized Total Code Domain Power Relative to Pilot(relative to total reverse channel pilot): -100.0 to +100.0 dB; 9.91 E+37 |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER64:FCHANNEL?" Queries the reverse fundamental channel code domain power information. |
This command provides a direct method for obtaining reverse supplemental channel one only total code domain power and total code domain power relative to the reverse pilot channel, without the need for specifying a bin number. This query returns 6 comma separated values. See Obtaining code channel information programmatically by code channel name for more information. |
|
I channel or Q channel: 0=I, 1=Q; 9.91 E +37 |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER:SCHANNEL1?" Queries the reverse supplemental channel code domain power information. |
This command provides a direct method for obtaining reverse supplemental channel one only total code domain power and total code domain power relative to the reverse pilot channel, without the need for specifying a bin number. This query returns 7 comma separated values. See Obtaining code channel information programmatically by code channel name for more information. |
|
I channel or Q channel: 0=I, 1=Q; 9.91 E +37 Normalized Total Code Domain Power Relative to Pilot(relative to total reverse channel pilot): -100.0 to +100.0 dB; 9.91 E+37 |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER64:SCHANNEL1?" Queries the reverse supplemental channel code domain power information. |
This command provides a direct method for obtaining reverse supplemental channel two only total code domain power and total code domain power relative to the reverse pilot channel, without the need for specifying a bin number. This query returns 6 comma separated values. See Obtaining code channel information programmatically by code channel name for more information. |
|
I channel or Q channel: 0=I, 1=Q; 9.91 E +37 |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER:SCHANNEL2?" Queries the reverse supplemental channel code domain power information. |
This command provides a direct method for obtaining reverse supplemental channel two only total code domain power and total code domain power relative to the reverse pilot channel, without the need for specifying a bin number. This query returns 7 comma separated values. See Obtaining code channel information programmatically by code channel name for more information. |
|
I channel or Q channel: 0=I, 1=Q; 9.91 E +37 Normalized Total Code Domain Power Relative to Pilot(relative to total reverse channel pilot): -100.0 to +100.0 dB; 9.91 E+37 |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER64:SCHANNEL2?" Queries the reverse supplemental channel code domain power information. |
Queries the code domain power measurement's pass/fail result indicating whether the |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER:IQINACTIVE:FAIL?" |
Queries the code domain power measurement's pass/fail result indicating whether the |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER64:IQINACTIVE:FAIL?" |
Queries the I-channel code domain power measurement results for up to 16 measurement graph bins (bars). This query returns a string consisting of 64 comma-separated values. These represent 4 values for each of 16 bins (maximum). See Bin Numbering System for more information. Since measurements will commonly have no more than 16 bins, higher numbered bins frequently return 9.91 E+37 (NAN) results. |
|
"FETCh:WQUality:CDPower[16]:ICHannel:ALL?" returns: 1 (active) or 0 (inactive), Walsh code, spread factor, and power for bin 0. The integer value following power for bin 0 will be the beginning of bin 1; 1 (active) or 0 (inactive), Walsh code, spread factor, and power for bin 1. This pattern will repeat until the values for the last bin (bin 15) have been returned. |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER:ICHANNEL:ALL?" |
Queries the I-channel code domain power measurement results for up to 64 measurement graph bins (bars). This query returns a string consisting of 256 comma-separated values. These represent 4 values for each of 64 bins (maximum). See Bin Numbering System for more information. Since measurements will commonly have no more than 64 bins, higher numbered bins frequently return 9.91 E+37 (NAN) results. |
|
"FETCh:WQUality:CDPower[64]:ICHannel:ALL?" returns: 1 (active) or 0 (inactive), Walsh code, spread factor, and power for bin 0. The integer value following power for bin 0 will be the beginning of bin 1; 1 (active) or 0 (inactive), Walsh code, spread factor, and power for bin 1. This pattern will repeat until the values for the last bin (bin 63) have been returned. |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER64:ICHANNEL:ALL?" |
Queries the measurement results for a specific bin (bar) on the I-channel code domain power graph. Bins are numbered beginning with 0 on the left and ending with the last bar on the right side of the graph. See Bin Numbering System for more information. To determine the current total number of bins, which will provide the range of <bin num>, use the FETCh:WQUality:CDPower:ICHannel:COUNt[:BIN]? command. |
|
Setting | <bin num> range: 0 to 15 |
Returns a string of 4 comma separated values for the specified bin: 1 (active) or 0 (inactive), Walsh code, spread factor, and power. |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER:ICHANNEL:BIN? 13" !Queries the I-channel code domain power level in bin 13. |
Queries the Q-channel code domain power measurement results for up to 16 measurement graph bins (bars). This query returns a string consisting of 64 comma-separated values. These represent 4 values for each of 16 bins (maximum). See Bin Numbering System for more information. Since measurements will commonly have no more than 16 bins, higher numbered bins frequently return 9.91 E+37 (NAN) results. |
|
"FETCh:WQUality:CDPower[16]:QCHannel:ALL?" returns: 1 (active) or 0 (inactive), Walsh code, spread factor, and power for bin 0. The integer value following power for bin 0 will be the beginning of bin 1; 1 (active) or 0 (inactive), Walsh code, spread factor, power for bin 1. This pattern will repeat until the values for the last bin (bin 15) have been returned. |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER16:QCHANNEL:ALL?" |
Queries the Q-channel code domain power measurement results for up to 64 measurement graph bins (bars). This query returns a string consisting of 256 comma-separated values. These represent 4 values for each of 16 bins (maximum). See Bin Numbering System for more information. Since measurements will commonly have no more than 64 bins, higher numbered bins frequently return 9.91 E+37 (NAN) results. |
|
"FETCh:WQUality:CDPower64:QCHannel:ALL?" returns: 1 (active) or 0 (inactive), Walsh code, spread factor, and power for bin 0. The integer value following power for bin 0 will be the beginning of bin 1; 1 (active) or 0 (inactive), Walsh code, spread factor, power for bin 1. This pattern will repeat until the values for the last bin (bin 63) have been returned. |
|
Programming Example OUTPUT 714;"FETCH:WQUALITY:CDPOWER64:QCHANNEL:ALL?" |
Queries the measurement results for a specific bin (bar) on the Q-channel code domain power graph. Bins are numbered beginning with 0 on the left and ending with the last bar on the right side of the graph. See Bin Numbering System for more information. To determine the current total number of bins, which will provide the range of <bin num>, use the FETCh:WQUality:CDPower:QCHannel:COUNt[:BIN]? command. |
|
Returns a string of 4 comma separated values for the specified bin: 1 (active) or 0 (inactive), Walsh code, spread factor, and power. |
|
OUTPUT 714;"FETCH:WQUALITY:CDPOWER:QCHANNEL:BIN? 13" !Queries the Q-channel power in bin 13. |
Queries the code domain power + noise measurement pass/fail indicator indicating whether the |
|
OUTPUT 714;"FETCH:WQUALITY:CDPNOISE:IQNOISE:FAIL?" |
Queries the code domain power + noise measurement pass/fail indicator indicating whether the |
|
OUTPUT 714;"FETCH:WQUALITY:CDPNOISE64:IQNOISE:FAIL?" |
Queries the I-channel code domain power + noise measurement results for up to 16 measurement graph bins (bars). This query returns a string consisting of 64 comma-separated values. These represent 4 values for each of 16 bins (maximum). See Bin Numbering System for more information. Since measurements will commonly have no more than 16 bins, higher numbered bins frequently return 9.91 E+37 (NAN) results. |
|
"FETCh:WQUality:CDPNoise[16]:ICHannel:ALL?" returns: Walsh code, spread factor, noise power, and power for bin 0. The integer value following power for bin 0 will be the beginning of bin 1; Walsh code, spread factor, noise power, and power for bin 1. This pattern will repeat until the values for the last bin (bin 15) have been returned. |
|
OUTPUT 714;"FETCH:WQUALITY:CDPNOISE:ICHANNEL:ALL?" |
Queries the I-channel code domain power + noise measurement results for up to 64 measurement graph bins (bars). This query returns a string consisting of 256 comma-separated values. These represent 4 values for each of 64 bins (maximum). See Bin Numbering System for more information. Since measurements will commonly have no more than 64 bins, higher numbered bins frequently return 9.91 E+37 (NAN) results. |
|
"FETCh:WQUality:CDPNoise64:ICHannel:ALL?" returns: Walsh code, spread factor, noise power, and power for bin 0. The integer value following power for bin 0 will be the beginning of bin 1; Walsh code, spread factor, noise power, and power for bin 1. This pattern will repeat until the values for the last bin (bin 63) have been returned. |
|
OUTPUT 714;"FETCH:WQUALITY:CDPNOISE64:ICHANNEL:ALL?" |
Queries the measurement results for a specific bin (bar) on the I-channel code domain power +noise graph. Bins are numbered beginning with 0 on the left and ending with the last bar on the right side of the graph. See Bin Numbering System for more information. To determine the current total number of bins, which will provide the range of <bin num>, use the FETCh:WQUality:CDPNoise:ICHannel:COUNt[:BIN]? command. |
|
Returns a string of 4 comma separated values for the specified bin: Walsh code, spread factor, noise power, and power. |
|
OUTPUT 714;"FETCH:WQUALITY:CDPNOISE:ICHANNEL:BIN? 13" !Queries the I-channel code domain power + noise measurement results for bin 13. |
Queries the Q-channel code domain power +noise measurement results for up to 16 measurement graph bins (bars). This query returns 64 comma-separated values. These represent 4 values for each of 16 bins (maximum). See Bin Numbering System for more information. Since measurements will commonly have no more than 16 bins, higher numbered bins frequently return 9.91 E+37 (NAN) results. |
|
"FETCh:WQUality[16]:CDPNoise:QCHannel:ALL?" returns: Walsh code, spread factor, noise power, and power for bin 0. The integer value following power for bin 0 will be the beginning of bin 1; Walsh code, spread factor, noise power, and power for bin 1. This pattern will repeat until the values for the last bin (bin 15) have been returned. |
|
OUTPUT 714;"FETCH:WQUALITY:CDPNOISE:QCHANNEL:ALL?" |
Queries the Q-channel code domain power +noise measurement results for up to 64 measurement graph bins (bars). This query returns 256 comma-separated values. These represent 4 values for each of 16 bins (maximum). See Bin Numbering System for more information. Since measurements will commonly have no more than 64 bins, higher numbered bins frequently return 9.91 E+37 (NAN) results. |
|
"FETCh:WQUality:CDPNoise64:QCHannel:ALL?" returns: Walsh code, spread factor, noise power, and power for bin 0. The integer value following power for bin 0 will be the beginning of bin 1; Walsh code, spread factor, noise power, and power for bin 1. This pattern will repeat until the values for the last bin (bin 63) have been returned. |
|
OUTPUT 714;"FETCH:WQUALITY:CDPNOISE64:QCHANNEL:ALL?" |
Queries the measurement results for a specific bin (bar) on the Q-channel code domain power +noise graph. Bins are numbered beginning with 0 on the left and ending with the last bar on the right side of the graph. See Bin Numbering System for more information. To determine the current total number of bins, which will provide the range of <bin num>, use the FETCh:WQUality:CDPNoise:QCHannel:COUNt[:BIN]? command. |
|
Returns a string of 4 comma separated values for the specified bin: Walsh code, spread factor, noise power, and power. |
|
OUTPUT 714;"FETCH:WQUALITY:CDPNOISE:QCHANNEL:BIN? 13" !Queries the Q-channel power in bin 13. |