Initiates and fetches an audio frequency analyzer measurement as a sequential operation. Measurement results are returned in the following order: integrity, average audio level, average SINAD, average audio distortion. |
|
Query |
|
Initiates and fetches an analog transmitter power measurement as a sequential operation. Measurement results are returned in the following order: integrity, average analog power. |
|
Query |
|
Initiates and fetches an access probe power measurement as a sequential operation. Measurement results are returned in the following order: integrity, access probe power. |
|
Query |
|
Initiates and fetches a code channel time and phase error measurement as a sequential operation. Measurement results are returned in the following order: integrity, time error pass/fail indication, phase error pass/fail indication. |
|
Query |
|
Queries the fast device tune (FDT) measurement results. Results are returned in the following order:
|
|
Query |
|
Test Application Revision: B.11 and above, with the required feature license |
Initiates and fetches the FER (frame error rate) measurements as a sequential operation. FER measurement results are returned in the following order: integrity, confidence limit pass/fail result, frame error ratio, frame error count, frames tested. |
|
Query |
|
Initiates and fetches a multi-tone audio measurement as a sequential operation. Measurement results are returned in the following order: integrity, and a comma separated list of all multi-tone audio measured levels for all 20 audio tones (in dB unit). For the levels, the query will return NAN (9.91E+37) for any audio tone that is turned off. For downlink audio measurements, the audio tones are turned off and on by SETup:CMAudio:GENerator:FREQuency:DOWNlink:PRESet . For uplink audio measurements, the audio tones can be turned off and on by SETup:CMAudio:GENerator:FREQuency:Uplink:PRESet , SETup:CMAudio:GENerator:FREQuency:Uplink:ALL[:SVALue] , or SETup:CMAudio:GENerator:LEVel:UPLink:ALL[:SAMPlitude] . |
|
|
|
Initiates and fetches the maximum/minimum power measurement as a sequential operation. Measurement results are returned in the following order: integrity, maximum power result, minimum power result. |
|
Query |
|
Initiates and fetches a channel power measurement as a sequential operation. Measurement results are returned in the following order: integrity, average channel power. If the multi-measurement state is on, the result represents the average of a number of channel power measurements. Multi-measurement state, by default, is off. To set up multi-measurements, see SETup:CPOWer:COUNt[:SNUMber] . |
|
Query |
|
Initiates and fetches Tx dynamic power measurement as a sequential operation. This query returns 101 comma-separated values, in the order of an integrity value followed by 100 power results. If the dynamic power measurement consists of less than 100 measurement steps (determined by FETCh:CTDPower:COUNt[:STEP]? ), the query results will be padded with NAN's (9.91 E+37), which means no results were available. |
|
Query |
|
Initiates and fetches the TX spurious emission measurement as a sequential operation. FER measurement results are returned in the following order: integrity,TX spurious emission pass/fail result, lower adjacent channel (-0.885 or -1.25 MHz) average spurious emissions, upper adjacent channel (+0.885 or +1.25 MHz) average spurious emissions, lower alternate channel (-1.98 MHz) average spurious emissions, upper alternate channel (+1.98 MHz) average spurious emissions. |
|
Query |
TX spurious emissions pass/fail result Lower adjacent channel spurious emissions Upper adjacent channel spurious emissions |
Initiates and fetches a digital average power measurement as a sequential operation. Measurement results are returned in the following order: integrity, digital average transmit power. If the multi-measurement state is on, the result represents the average of a number of digital average power measurements. Multi-measurement state, by default, is off. To set up multi-measurements, see SETup:DAPower:COUNt[:SNUMber] . |
|
Query |
|
Initiates and fetches the a DTMF measurement as a sequential operation. Measurement results are returned in the following order: integrity, number of characters, then 16 sets of 9 comma-separated values in the following order: character n symbol, character n low tone frequency, character n low tone frequency error, character n low tone phase deviation, character n high tone frequency, character n high tone frequency error, Character n high tone phase deviation, character n on time, character n off time. n is from 0 to 15. |
|
Character n Low Tone Frequency Character n Low Tone Frequency Error Character n Low Tone Phase Deviation Character n High Tone Frequency Character n High Tone Frequency Error |
|
Initiates and fetches an FM measurement as a sequential operation. Measurement results are returned in the following order: integrity, average frequency deviation, average distortion. The distortion measurement must be enabled before a measurement result (other than 9.91E+37) is reported. See SETup:AFANalyzer:SDIStortion:STATe . |
|
Query |
|
Initiates and fetches a graphical access probe power measurement cycle as a sequential operation. This measurement returns results in the following order: integrity, followed by a comma-separated list of 20 access probe power results. If the graphical access probe power measurement consisted of less than 20 access probes, the query results will be padded with NAN's (9.91 E37) to make the number of measurements equal 20. If the test set does not receive the expected number of access probes and no timeouts have been set up this command will hang indefinitely. |
|
Query |
|
Initiates and fetches a graphical access probe power measurement cycle as a sequential operation. This measurement returns results in the following order: integrity, followed by a comma-separated list of 60 access probe power results. If the graphical access probe power measurement consisted of less than 60 access probes, the query results will be padded with NAN's (9.91 E37) to make the number of measurements equal 60. If the test set does not receive the expected number of access probes and no timeouts have been set up this command will hang indefinitely. |
|
Query |
|
Initiates and fetches a frequency stability measurement as a sequential operation. Measurement results are returned in the following order: integrity, worst-case frequency error, average frequency. |
|
Query |
|
Initiates and fetches a gated power measurement as a sequential operation. Measurement results are returned in the following order: integrity, gated power pass/fail indication. |
|
Query |
|
Initiates and fetches a swept audio measurement as a sequential operation. Measurement results are returned in the following order: integrity, and a comma separated list of average audio level and average audio distortion for each frequency point in the sweep. For frequencies about 10 kHz, the measurement will return 9.91 E+37. |
|
|
Initiates and fetches the signaling tone measurements as a sequential operation. Measurement results are returned in the following order: integrity, positive peak deviation, negative peak deviation, frequency error and frequency. When multi-measurement is enabled, the average positive peak deviation, average negative peak deviation, average frequency error and average frequency from all the measurements are returned. |
|
Average positive peak deviation |
|
Queries (initiates and fetches) one spectrum monitor measurement as a sequential operation. Returns a comma separated list of 401 points representing the amplitude results of the trace data. |
|
Initiates and fetches the TDSO FER (test data service option (SO32) frame error rate) measurements as a sequential operation. FER measurement results are returned in the following order: integrity, frame error rate (%), received good frames, received blank frames, transmitted good frames, transmitted blank frames, frame error rate confidence (%). |
|
Query |
|
Initiates and fetches a time response of open loop power control measurement as a sequential operation. Measurement results are returned in the following order: integrity, time response of open loop power control pass/fail result. For the pass/fail result, 0 = pass, 1 = fail, 9.91 E+37 = undefined. |
|
|
Initiates and fetches the Wideband Data Deviation measurement as a sequential operation. Measurement results are returned in the following order: integrity, maximum positive peak frequency deviation, maximum negative peak frequency deviation, settled positive peak frequency deviation, settled negative peak frequency deviation. If the measurement gets more than one wideband data burst, it measures the first one. |
|
Maximum positive peak frequency deviation Minimum negative peak frequency deviation |
|
Initiates and fetches the waveform quality measurements as a sequential operation. Measurement results are returned in the following order: integrity, rho, frequency error, time error, carrier feedthrough, phase error, magnitude error, EVM. If the multi-measurement state is on, each result represents the average of a number of waveform quality measurements. Multi-measurement state, by default, is off. To set up multi-measurements, see SETup:WQUality:COUNt[:SNUMber] . |
|
Query |