Setting Control Channel Parameters

Setting Control Channel Parameters

Last updated: July 7, 2009

This section is only applicable to the lab application and to a test application with the required feature license.

Overview

When the test set is set to the protocol revision 7 (IS-2000-A) or above (see Protocol Revisions ), either the pair of forward paging/reverse access (F-PCH/R-ACH) control channels or the set of the forward broadcast/forward common control/reverse enhanced access (F-BCCH/F-CCCH/R-EACH) control channels can be selected and used for the transmission of overhead and control information to or from the mobile station. This is different from the test set with protocol revisions 6 (IS-2000-0) or less which only supports the F-PCH/R-ACH control channels.

The test set with F-BCCH/F-CCCH channels configuration will send overhead messages on the primary F-BCCH (see IS-2000 Primary Broadcast Control Channel Overhead Messages (P_REV > = 7) ) and the mobile station directed messages (such as General Page message, etc.) on the F-CCCH. See also Settable Fields in Overhead Messages .

To access the Control Channel Parameters menu from the front panel, see A. Control Channel Parameters .

Control Channels Configuration

IS-2000 System IS-95 System

Protocol Rev 1

7 (IS-2000-A) 6 (IS-2000-0) All Supported
Current control channels

F-BCCH/F-CCCH/R-EACH, or

F-PCH/R-ACH

F-PCH/R-ACH
  1. See Protocol Revisions for details.

Control Channel Configuration

The Control Channel Configuration ( CALL[:CELL]:PROTocol:CCHannel:CONFigure ) setting applies to protocol revision 7 (IS-2000-A) or above and is used to specify which forward common control channels are generated by the test set and which access channel is expected to be used by the mobile station. When the F-BCCH/F-CCCH/R-EACH is selected, the parameters relating to the F-BCCH/F-CCCH channels are displayed in the Control Channel Parameters menu. When the F-PCH/R-ACH is selected, the paging channel related parameters are shown. Also, this selection will toggle the F3 softkey label to Access Parameters (see Setting Access Parameters ) or Enhanced Access Parms (see Setting Enhanced Access Parameters ) and update the Cell Information screen to display the current control channels information.

Changing this setting may be rejected and will revert to the previous value.

The F-PCH/R-ACH is the only pair of control channels available for protocol revision less than seven.

Control Channel Parameters (F-BCCH/F-CCCH/R-EACH)

When the F-BCCH/F-CCCH/R-EACH is selected, the following parameters relating to the F-BCCH/F-CCCH channels are displayed in the Control Channel Parameters menu:

Control Channel Parameters (F-PCH/R-ACH)

When the F-PCH/R-ACH is selected, the following paging channel parameters can be set from the Control Channel Parameters menu:

Operating Considerations

Related Topics


Manual Operation: A. Control Channel Parameters

Configuring the F-BCCH/F-CCCH Control Channels

Setting Enhanced Access Parameters

Settable Fields in Overhead Messages